Input Signal | 4-20mA DC, 1-5V DC, 0-10V DC, HART Protocol, Etc |
---|---|
Protection Level | IP66 |
Diagnostic Function | It Can Automatically Detect Faults And Device Status, And Provide Warning And Fault Prompt Information |
Accuracy | Up To 0.075% Under Nominal Conditions |
Deadband Adjustment | Adjustable Deadband To Accommodate Different Applications |
Power Supply | 12-42V DC Power Supply |
---|---|
Local Display | 4-digit LCD Screen, Which Can Display Current Analog Input Value, Output Value, Set Value, And Device Status Information |
Protection Level | IP66 |
Digital Communication Interface | Optional RS485 Modbus RTU Or FOUNDATION Fieldbus Interface |
Deadband Adjustment | Adjustable Deadband To Accommodate Different Applications |
Warranty | 1 Years |
---|---|
Model Number | DVC6200 |
Mounting Type | Integral Mounted |
Data Interface | Wired |
Max Outlet Pressure | 145 Psig |
Rated Flow Coefficient | Maximum CV Value Of 470 |
---|---|
Valve Connection | ISO 5211 Direct Mounting Or VDI/VDE 3845 Mounting With Adapter |
Material | Aluminum Alloy Or Stainless Steel |
Valve Travel Range | 10mm To 100mm |
Zero Point Drift | Less Than 0.1% Of The Maximum Travel Value |
Rated Flow Coefficient | Maximum CV Value Of 470 |
---|---|
Output Signal | 4-20mA, HART, PROFIBUS PA Or FOUNDATION Fieldbus |
Valve Position Feedback | Provides Digital Position Feedback Through Hall Sensors Or Analog Position Feedback Through Potentiometers |
Protection Rating | IP66/67 |
Valve Travel Range | 10mm To 100mm |
Diagnostic Functions | Provides Status Reports And Fault Information, Supports Equipment Management And Maintenance |
---|---|
Linearity | Less Than 0.5% Of The Maximum Travel Value |
Zero Point Drift | Less Than 0.1% Of The Maximum Travel Value |
Material | Aluminum Alloy Or Stainless Steel |
Suitable Media | Non-corrosive Media Such As Liquids, Gases, And Steam |
Positioning Accuracy | Typically ±0.5% |
---|---|
Power Supply Voltage | 24VDC Or 110-240VAC |
Operating Temperature Range | -40°C To +85°C |
Mounting | Vertical Or Suspended Mounting Options |
Accessories | Overload Protection, Manual Operation, Protective Cover, And Transition Plate |
Accessories | Overload Protection, Manual Operation, Protective Cover, And Transition Plate |
---|---|
Positioning Accuracy | Typically ±0.5% |
Valve Stroke Range | Typically 20mm, 40mm, 60mm, Or 100mm |
Mounting | Vertical Or Suspended Mounting Options |
Output Signal | Typically 4-20mA Or 0-10VDC |
Operating Temperature Range | -40°C To +85°C |
---|---|
Positioning Accuracy | Typically ±0.5% |
Mounting | Vertical Or Suspended Mounting Options |
Valve Stroke Range | Typically 20mm, 40mm, 60mm, Or 100mm |
Power Supply Voltage | 24VDC Or 110-240VAC |
Weight | 3.5KG |
---|---|
Maximum Output Torque | 600 Nm |
Rated Pressure | Maximum 10 Bar |
Display Screen | LCD Display Screen, Which Can Display Current Position, Power Status, And Other Information |
Power Supply | 4V DC, 120V AC, Or 240V AC |