Input Signal | 4-20mA DC, 1-5V DC, 0-10V DC, HART Protocol, Etc |
---|---|
Protection Level | IP66 |
Diagnostic Function | It Can Automatically Detect Faults And Device Status, And Provide Warning And Fault Prompt Information |
Accuracy | Up To 0.075% Under Nominal Conditions |
Deadband Adjustment | Adjustable Deadband To Accommodate Different Applications |
Power Supply | 12-42V DC Power Supply |
---|---|
Local Display | 4-digit LCD Screen, Which Can Display Current Analog Input Value, Output Value, Set Value, And Device Status Information |
Protection Level | IP66 |
Digital Communication Interface | Optional RS485 Modbus RTU Or FOUNDATION Fieldbus Interface |
Deadband Adjustment | Adjustable Deadband To Accommodate Different Applications |
Accessories | Overload Protection, Manual Operation, Protective Cover, And Transition Plate |
---|---|
Positioning Accuracy | Typically ±0.5% |
Operating Temperature Range | -40°C To +85°C |
Mounting | Vertical Or Suspended Mounting Options |
Power Supply Voltage | 24VDC Or 110-240VAC |
Accessories | Overload Protection, Manual Operation, Protective Cover, And Transition Plate |
---|---|
Positioning Accuracy | Typically ±0.5% |
Valve Stroke Range | Typically 20mm, 40mm, 60mm, Or 100mm |
Mounting | Vertical Or Suspended Mounting Options |
Output Signal | Typically 4-20mA Or 0-10VDC |
Operating Temperature Range | -40°C To +85°C |
---|---|
Positioning Accuracy | Typically ±0.5% |
Mounting | Vertical Or Suspended Mounting Options |
Valve Stroke Range | Typically 20mm, 40mm, 60mm, Or 100mm |
Power Supply Voltage | 24VDC Or 110-240VAC |
Input Signal | 4~20mA DC |
---|---|
Impedance | 500Ω (20mA DC) |
Supply Pressure | 0.14~0.7MPa |
Stroke | Linear Type:10~150mm, Rotary Type:0~90º |
Air Connection | PT1/4, NPT1/4 |
Rated Flow Coefficient | Maximum CV Value Of 470 |
---|---|
Valve Connection | ISO 5211 Direct Mounting Or VDI/VDE 3845 Mounting With Adapter |
Material | Aluminum Alloy Or Stainless Steel |
Valve Travel Range | 10mm To 100mm |
Zero Point Drift | Less Than 0.1% Of The Maximum Travel Value |
Rated Operating Pressure | Up To 16 Bar |
---|---|
Diagnostic Functions | Provides Status Reports And Fault Information, Supports Equipment Management And Maintenance |
Suitable Media | Non-corrosive Media Such As Liquids, Gases, And Steam |
Linearity | Less Than 0.5% Of The Maximum Travel Value |
Operating Temperature Range | -40°C To +85°C |
Conformity/Linearity | ± 0.5% Full Span |
---|---|
Supply Pressure Effect | 0.05% Per Psi Unit |
Name | Masoneilan SVI FF |
Operating | -40° F To 185° F (-40° C To 85° C) |
Accuracy | ± 0.5% |
Safety Features | Overvoltage Protection, Reverse Polarity Protection, Short-circuit Protection |
---|---|
Programmability | Programmable Through FoxCom Or PC Software |
Optional Accessories | Pressure Modules, Temperature Sensors, Communication Cables, PC Software |
Power Output | 24V DC Nominal, 20 MA Max |
Ramp Function | User-defined Ramp Function With Adjustable Time |