Product Name | Control Valve Positioner |
---|---|
Model | SA/CL |
Temperature Of Media | High Temperature |
Pressure | High Pressure |
Operating Temperature | -20 To 55°C (-4 To 122°F) |
Product Name | Control Valve Positioner |
---|---|
Model | Foxboro SRI990 |
Temperature Of Media | High Temperature |
Pressure | High Pressure |
Operating Temperature | -20 To 55°C (-4 To 122°F) |
Product Name | Control Valve Positioner |
---|---|
Model | Varies |
Temperature Of Media | High Temperature |
Pressure | High Pressure |
Operating Temperature | -20 To 55°C (-4 To 122°F) |
Protection Level | IP66 |
---|---|
Deadband Adjustment | Adjustable Deadband To Accommodate Different Applications |
Diagnostic Function | It Can Automatically Detect Faults And Device Status, And Provide Warning And Fault Prompt Information |
Local Display | 4-digit LCD Screen, Which Can Display Current Analog Input Value, Output Value, Set Value, And Device Status Information |
Power Supply | 12-42V DC Power Supply |
Input Signal | 4-20mA DC, 1-5V DC, 0-10V DC, HART Protocol, Etc |
---|---|
Protection Level | IP66 |
Diagnostic Function | It Can Automatically Detect Faults And Device Status, And Provide Warning And Fault Prompt Information |
Accuracy | Up To 0.075% Under Nominal Conditions |
Deadband Adjustment | Adjustable Deadband To Accommodate Different Applications |
Deadband Adjustment | Adjustable Deadband To Accommodate Different Applications |
---|---|
Digital Communication Interface | Optional RS485 Modbus RTU Or FOUNDATION Fieldbus Interface |
Protection Level | IP66 |
Output Signal | 4-20mA DC, HART Protocol, Etc |
Local Display | 4-digit LCD Screen, Which Can Display Current Analog Input Value, Output Value, Set Value, And Device Status Information |
Rated Flow Coefficient | Maximum CV Value Of 470 |
---|---|
Output Signal | 4-20mA, HART, PROFIBUS PA Or FOUNDATION Fieldbus |
Valve Position Feedback | Provides Digital Position Feedback Through Hall Sensors Or Analog Position Feedback Through Potentiometers |
Protection Rating | IP66/67 |
Valve Travel Range | 10mm To 100mm |
Operating Temperature Range | -40℃ To 70℃ |
---|---|
Digital Communication Interface | Optional RS485 Modbus RTU Or FOUNDATION Fieldbus Interface |
Protection Level | IP66 |
Deadband Adjustment | Adjustable Deadband To Accommodate Different Applications |
Diagnostic Function | It Can Automatically Detect Faults And Device Status, And Provide Warning And Fault Prompt Information |
Condition | New |
---|---|
Hysteresis + DeadBand | +/- 0.3 Percent Full Span |
Minimum Current Signal | 3.2 MA |
Pneumatics | Air Or Sweet Natural Gas – Regulated And Filtered |
Signal Communication | HART 5 Or 7 Over 4-20mA |
Shell Material | Industrial Aluminum Housing |
---|---|
Minimum Current Signal | 3.2mA |
Case/Cover | Aluminum ASTM 360 |
Required Terminal Voltage | 9Vdc At 20mA |
Valve Setpoint | 4-20mA, 450 Ohms Input Resistance |