| Type | Vortex Flowmeter |
|---|---|
| Material | Stainless Steel |
| Process Pressure | Max. 100 Barg/ 1450 Psig |
| Digital Outputs | FOUNDATION Fieldbus, HART , Profibus-PA |
| Analogue Outputs | 4~20 MA |
| Battery Life | Approx. 30 Hours Continuous Use At 20 MA Output |
|---|---|
| Accessories | Carrying Case, Test Leads, Alligator Clips, User Manual, Certificate Of Calibration |
| Power Output | 24V DC Nominal, 30 MA Max |
| Optional Accessories | Pressure Modules, Temperature Sensors, Communication Cables, PC Software |
| Power Supply | 9V DC 4 X 1.5V AA Batteries Or Rechargeable Battery |
| Stability | ±0.125% |
|---|---|
| Output | 4-20 MA With Digital Signal |
| Temperature Range | -40 °C To +85 °C |
| Protocols | HART 5/6/7, FOUNDATION Fieldbus, PROFIBUS PA |
| Process Connections | 1/2" NPT, Flanged, Manifold Options |
| Accuracy | 0.025% Full Scale |
|---|---|
| Output Stability | ±0.01% Of Output Reading Per Hour |
| Communication Interface | HART, FoxCom, RS-232, RS-485 |
| Display | LCD Display, 2 Lines X 16 Characters |
| Weight | Approx. 300g |
| Safety Features | Overvoltage Protection, Reverse Polarity Protection, Short-circuit Protection |
|---|---|
| Programmability | Programmable Through FoxCom Or PC Software |
| Optional Accessories | Pressure Modules, Temperature Sensors, Communication Cables, PC Software |
| Power Output | 24V DC Nominal, 20 MA Max |
| Ramp Function | User-defined Ramp Function With Adjustable Time |
| Material | Stainless Steel |
|---|---|
| Process Connection | Flanges Or Swagelok, Sanitary Threads, Sterile Fittings |
| Process Temperature | -40°C To +210°C (-40°F To +410°F) |
| Nominal Size | DN6 To DN50 |
| Process Pressure | Up To 300 Bar (4,351 Psi) |
| Protection | IP65/IP67 |
|---|---|
| Storage Function | 1000 Record Can Be Saved |
| Fluid Media | Air, Water, Oil, Gas |
| Alarm Outputs | No Flow, High Alarm And Low Alarm |
| Medium Temperature | Up To 400 °C |
| Accuracy | Standard: Up To 0.05 % |
|---|---|
| Process Temperature | -40°C...+110°C |
| Rated Temperature | -40~200℃ |
| Communication Interface | Depends On Specific Instrument |
| Condition | New |
| Measuring Range | Up To 2000 Psi (137,89 Bar) Differential |
|---|---|
| Temperature Range | -200°C To +850°C |
| Sensitivity | Up To 150:1 |
| Flange Options | ANSI Class 150 To 1500 |
| Weight | Depends On Specific Instrument |
| Turndown | 38:1 |
|---|---|
| Antenna Type | Lens Type |
| Power Supply | 10.5-35V DC (Ex I: 10.5-30V DC) |
| Voltage | AC / DC 220V, AC 380V,etc |
| Output Signal | 4 To 20 MA With HART |