| Input Signal | 4-20mA DC, 1-5V DC, 0-10V DC, HART Protocol, Etc |
|---|---|
| Protection Level | IP66 |
| Diagnostic Function | It Can Automatically Detect Faults And Device Status, And Provide Warning And Fault Prompt Information |
| Accuracy | Up To 0.075% Under Nominal Conditions |
| Deadband Adjustment | Adjustable Deadband To Accommodate Different Applications |
| Power Supply | 12-42V DC Power Supply |
|---|---|
| Local Display | 4-digit LCD Screen, Which Can Display Current Analog Input Value, Output Value, Set Value, And Device Status Information |
| Protection Level | IP66 |
| Digital Communication Interface | Optional RS485 Modbus RTU Or FOUNDATION Fieldbus Interface |
| Deadband Adjustment | Adjustable Deadband To Accommodate Different Applications |
| Rated Flow Coefficient | Maximum CV Value Of 470 |
|---|---|
| Valve Connection | ISO 5211 Direct Mounting Or VDI/VDE 3845 Mounting With Adapter |
| Material | Aluminum Alloy Or Stainless Steel |
| Valve Travel Range | 10mm To 100mm |
| Zero Point Drift | Less Than 0.1% Of The Maximum Travel Value |
| Rated Flow Coefficient | Maximum CV Value Of 470 |
|---|---|
| Output Signal | 4-20mA, HART, PROFIBUS PA Or FOUNDATION Fieldbus |
| Valve Position Feedback | Provides Digital Position Feedback Through Hall Sensors Or Analog Position Feedback Through Potentiometers |
| Protection Rating | IP66/67 |
| Valve Travel Range | 10mm To 100mm |
| Zero Point Drift | Less Than 0.1% Of The Maximum Travel Value |
|---|---|
| Valve Travel Range | 10mm To 100mm |
| Valve Connection | ISO 5211 Direct Mounting Or VDI/VDE 3845 Mounting With Adapter |
| Protection Rating | IP66/67 |
| Linearity | Less Than 0.5% Of The Maximum Travel Value |
| Diagnostic Functions | Provides Status Reports And Fault Information, Supports Equipment Management And Maintenance |
|---|---|
| Linearity | Less Than 0.5% Of The Maximum Travel Value |
| Zero Point Drift | Less Than 0.1% Of The Maximum Travel Value |
| Material | Aluminum Alloy Or Stainless Steel |
| Suitable Media | Non-corrosive Media Such As Liquids, Gases, And Steam |
| Positioning Accuracy | Typically ±0.5% |
|---|---|
| Power Supply Voltage | 24VDC Or 110-240VAC |
| Operating Temperature Range | -40°C To +85°C |
| Mounting | Vertical Or Suspended Mounting Options |
| Accessories | Overload Protection, Manual Operation, Protective Cover, And Transition Plate |
| Accessories | Overload Protection, Manual Operation, Protective Cover, And Transition Plate |
|---|---|
| Positioning Accuracy | Typically ±0.5% |
| Valve Stroke Range | Typically 20mm, 40mm, 60mm, Or 100mm |
| Mounting | Vertical Or Suspended Mounting Options |
| Output Signal | Typically 4-20mA Or 0-10VDC |
| Positioning Accuracy | Typically ±0.5% |
|---|---|
| Valve Stroke Range | Typically 20mm, 40mm, 60mm, Or 100mm |
| Output Signal | Typically 4-20mA Or 0-10VDC |
| Mounting | Vertical Or Suspended Mounting Options |
| Operating Temperature Range | -40°C To +85°C |
| Operating Temperature Range | -40°C To +85°C |
|---|---|
| Positioning Accuracy | Typically ±0.5% |
| Mounting | Vertical Or Suspended Mounting Options |
| Valve Stroke Range | Typically 20mm, 40mm, 60mm, Or 100mm |
| Power Supply Voltage | 24VDC Or 110-240VAC |