| Output Resolution | 0.001 MA |
|---|---|
| Temperature Range | -10°C To 55°C |
| Dimensions | 144 Mm X 80 Mm X 44 Mm |
| Display | LCD Display, 2 Lines X 16 Characters |
| Humidity Range | 0% To 95% (non-condensing) |
| Safety Features | Overvoltage Protection, Reverse Polarity Protection, Short-circuit Protection |
|---|---|
| Temperature Range | -10°C To 55°C |
| Output Resolution | 0.001 MA |
| Ramp Function | User-defined Ramp Function With Adjustable Time |
| Accuracy | 0.01% Full Scale |
| Accessories | Carrying Case, Test Leads, Alligator Clips, User Manual, Certificate Of Calibration |
|---|---|
| Power Output | 24V DC Nominal, 30 MA Max |
| Output Resolution | 0.001 MA |
| Power Supply | 9V DC 4 X 1.5V AA Batteries Or Rechargeable Battery |
| Display | LCD Display, 2 Lines X 16 Characters |
| Accuracy | 0.01% Full Scale |
|---|---|
| Certifications | CE, CSA, FM, ATEX, IECEx, GOST-R |
| Optional Accessories | Pressure Modules, Temperature Sensors, Communication Cables, PC Software |
| Power Supply | 9V DC 4 X 1.5V AA Batteries Or Rechargeable Battery |
| Output Resolution | 0.001 MA |
| Deadband Adjustment | Adjustable Deadband To Accommodate Different Applications |
|---|---|
| Digital Communication Interface | Optional RS485 Modbus RTU Or FOUNDATION Fieldbus Interface |
| Protection Level | IP66 |
| Output Signal | 4-20mA DC, HART Protocol, Etc |
| Local Display | 4-digit LCD Screen, Which Can Display Current Analog Input Value, Output Value, Set Value, And Device Status Information |
| Protection Level | IP66 |
|---|---|
| Deadband Adjustment | Adjustable Deadband To Accommodate Different Applications |
| Diagnostic Function | It Can Automatically Detect Faults And Device Status, And Provide Warning And Fault Prompt Information |
| Local Display | 4-digit LCD Screen, Which Can Display Current Analog Input Value, Output Value, Set Value, And Device Status Information |
| Power Supply | 12-42V DC Power Supply |
| Input Signal | 4-20mA DC, 1-5V DC, 0-10V DC, HART Protocol, Etc |
|---|---|
| Protection Level | IP66 |
| Diagnostic Function | It Can Automatically Detect Faults And Device Status, And Provide Warning And Fault Prompt Information |
| Accuracy | Up To 0.075% Under Nominal Conditions |
| Deadband Adjustment | Adjustable Deadband To Accommodate Different Applications |
| Power Supply | 12-42V DC Power Supply |
|---|---|
| Local Display | 4-digit LCD Screen, Which Can Display Current Analog Input Value, Output Value, Set Value, And Device Status Information |
| Protection Level | IP66 |
| Digital Communication Interface | Optional RS485 Modbus RTU Or FOUNDATION Fieldbus Interface |
| Deadband Adjustment | Adjustable Deadband To Accommodate Different Applications |
| Operating Temperature Range | -40℃ To 70℃ |
|---|---|
| Digital Communication Interface | Optional RS485 Modbus RTU Or FOUNDATION Fieldbus Interface |
| Protection Level | IP66 |
| Deadband Adjustment | Adjustable Deadband To Accommodate Different Applications |
| Diagnostic Function | It Can Automatically Detect Faults And Device Status, And Provide Warning And Fault Prompt Information |
| Rated Flow Coefficient | Maximum CV Value Of 470 |
|---|---|
| Valve Connection | ISO 5211 Direct Mounting Or VDI/VDE 3845 Mounting With Adapter |
| Material | Aluminum Alloy Or Stainless Steel |
| Valve Travel Range | 10mm To 100mm |
| Zero Point Drift | Less Than 0.1% Of The Maximum Travel Value |