| Nominal Diameter Range | DN 8 To 250 (⅜ To 10") |
|---|---|
| Measuring Range | 0 To 2 200 000 Kg/h (0 To 80 840 Lb/min) |
| Medium Temperature Range | Standard: –50 To +150 °C (–58 To +302 °F) Option: –50 To +240 °C (–58 To +464 °F) High Temperatur Option: –50 To +350 °C (–58 To +662 °F) Option: –196 To +150 °C (–320 To +302 °F) |
| Mass Flow (liquid) | ±0.10 % (standard), 0.05 % (option) |
| Mass Flow (gas) | ±0.25 % |
| Volume Flow (liquid) | ±0.10 % |
|---|---|
| Measuring Range | 0 To 2 200 000 Kg/h (0 To 80 840 Lb/min) |
| Wetted Materials | Measuring Tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022) Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022); 1.4301 (F304) |
| Nominal Diameter Range | DN 8 To 250 (⅜ To 10") |
| Medium Temperature Range | Standard: –50 To +150 °C (–58 To +302 °F) Option: –50 To +240 °C (–58 To +464 °F) High Temperatur Option: –50 To +350 °C (–58 To +662 °F) Option: –196 To +150 °C (–320 To +302 °F) |
| Connectivity | Flange |
|---|---|
| Material | Stainless Steel, ABS, Metal |
| Standard Medium Temperature Range | -50 To +150 °C (-58 To +302 °F) |
| Max. Process Pressure | PN40 / Cl. 300 / 20K |
| Measurement Range | 0 To 2 200 000 Kg/h (0 To 80 840 Lb/min) |
| Medium Temperature Range | -40 To +150 °C (-40 To +302 °F) |
|---|---|
| Accuracy | ±0.15 % |
| Measurement Range | 0 To 180 000 Kg/h (0 To 6615 Lb/min) |
| Medium | Liquid, Gas |
| Liquid, Gas | PN 100, Class 600, 63K |
| Wetted Materials | Measuring Tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022) Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022); 1.4301 (F304) |
|---|---|
| Measuring Range | 0 To 2 200 000 Kg/h (0 To 80 840 Lb/min) |
| Density (liquid) | ±0.0005 G/cm³ |
| Mass Flow (gas) | ±0.25 % |
| Nominal Diameter Range | DN 8 To 250 (⅜ To 10") |
| Weight | 10-20KG |
|---|---|
| Material Certificates | 3.1 Material NACE MR0175/MR0103, PMI; Welding Test Acc. To EN ISO, ASME, NORSOK |
| Product Safety | CE, C-tick, EAC Marking |
| Functional Safety | Functional Safety According To IEC 61508, Applicable In Safety-relevant Applications In Accordance With IEC 61511 |
| Model | Proline Promass F 500 |
| Medium Temperature Range | Standard: –50 To +150 °C (–58 To +302 °F) Option: –50 To +240 °C (–58 To +464 °F) High Temperatur Option: –50 To +350 °C (–58 To +662 °F) Option: –196 To +150 °C (–320 To +302 °F) |
|---|---|
| Volume Flow (liquid) | ±0.10 % |
| Measuring Range | 0 To 2 200 000 Kg/h (0 To 80 840 Lb/min) |
| Measured Variables | Mass Flow, Density, Temperature, Volume Flow, Corrected Volume Flow, Reference Density, Concentration |
| Nominal Diameter Range | DN 8 To 250 (⅜ To 10") |
| Connectivity | Flange |
|---|---|
| Material | Stainless Steel, ABS, Metal |
| Standard Medium Temperature Range | -50 To +150 °C (-58 To +302 °F) |
| Max. Process Pressure | PN40 / Cl. 300 / 20K |
| Measurement Range | 0 To 2 200 000 Kg/h (0 To 80 840 Lb/min) |
| Product Name | Proline Promass F 300 Coriolis Flowmeter |
|---|---|
| Nominal Diameter Range | DN 8 To 250 |
| Measuring Range | 0 To 2 200 000 Kg/h (0 To 80 840 Lb/min) |
| Max. Process Pressure | PN 100, Class 600, 63K |
| Sensor Housing Material | Standard: 1.4301 (304) /Option: 1.4404 (316/316L) |
| Working Voltage | DC(18~30)V |
|---|---|
| Conditional | New |
| Maximum Pressure | 200 Barg |
| Protection Level | IP67 |
| Output Accuracy | ±1%F.S |