| Nominal Diameter Range | DN 8 To 250 (⅜ To 10") |
|---|---|
| Measuring Range | 0 To 2 200 000 Kg/h (0 To 80 840 Lb/min) |
| Medium Temperature Range | Standard: –50 To +150 °C (–58 To +302 °F) Option: –50 To +240 °C (–58 To +464 °F) High Temperatur Option: –50 To +350 °C (–58 To +662 °F) Option: –196 To +150 °C (–320 To +302 °F) |
| Mass Flow (liquid) | ±0.10 % (standard), 0.05 % (option) |
| Mass Flow (gas) | ±0.25 % |
| Volume Flow (liquid) | ±0.10 % |
|---|---|
| Measuring Range | 0 To 2 200 000 Kg/h (0 To 80 840 Lb/min) |
| Wetted Materials | Measuring Tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022) Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022); 1.4301 (F304) |
| Nominal Diameter Range | DN 8 To 250 (⅜ To 10") |
| Medium Temperature Range | Standard: –50 To +150 °C (–58 To +302 °F) Option: –50 To +240 °C (–58 To +464 °F) High Temperatur Option: –50 To +350 °C (–58 To +662 °F) Option: –196 To +150 °C (–320 To +302 °F) |
| Connectivity | Flange |
|---|---|
| Material | Stainless Steel, ABS, Metal |
| Standard Medium Temperature Range | -50 To +150 °C (-58 To +302 °F) |
| Max. Process Pressure | PN40 / Cl. 300 / 20K |
| Measurement Range | 0 To 2 200 000 Kg/h (0 To 80 840 Lb/min) |
| Medium Temperature Range | -40 To +150 °C (-40 To +302 °F) |
|---|---|
| Accuracy | ±0.15 % |
| Measurement Range | 0 To 180 000 Kg/h (0 To 6615 Lb/min) |
| Medium | Liquid, Gas |
| Liquid, Gas | PN 100, Class 600, 63K |
| Medium Temperature Range | Standard: –50 To +150 °C (–58 To +302 °F) Option: –50 To +240 °C (–58 To +464 °F) High Temperatur Option: –50 To +350 °C (–58 To +662 °F) Option: –196 To +150 °C (–320 To +302 °F) |
|---|---|
| Volume Flow (liquid) | ±0.10 % |
| Measuring Range | 0 To 2 200 000 Kg/h (0 To 80 840 Lb/min) |
| Measured Variables | Mass Flow, Density, Temperature, Volume Flow, Corrected Volume Flow, Reference Density, Concentration |
| Nominal Diameter Range | DN 8 To 250 (⅜ To 10") |
| Connectivity | Flange |
|---|---|
| Material | Stainless Steel, ABS, Metal |
| Standard Medium Temperature Range | -50 To +150 °C (-58 To +302 °F) |
| Max. Process Pressure | PN40 / Cl. 300 / 20K |
| Measurement Range | 0 To 2 200 000 Kg/h (0 To 80 840 Lb/min) |
| Max. Process Pressure | PN 100, Class 600, 20K |
|---|---|
| Outputs | 4-20 MA HART (passive) |
| Digital Communication | HART, PROFIBUS PA, FOUNDATION Fieldbus |
| Max. Measurement Error | Volume Flow (standard): ±0.5 % O.r. ± 1 Mm/s (0.04 In/s) |
| Power Supply | DC 12 To 35 V |
| Accuracy | Standard: Up To 0.05 % |
|---|---|
| Process Temperature | -40°C...+110°C |
| Rated Temperature | -40~200℃ |
| Communication Interface | Depends On Specific Instrument |
| Condition | New |
| Approval; Transmitter + Sensor | ATEX+IECEx; Z0/1, Z21, Ex De, IIC/IIIC |
|---|---|
| Power Supply | DC 24V |
| Output; Input 1 | Modbus RS485 |
| Output; Input 2 | 4-20mA |
| Output; Input 3 | Configurable I/O Default Off |
| Mass Flow (liquid) | ±0.10 % (standard), 0.05 % (option) |
|---|---|
| Density (liquid) | ±0.0005 G/cm³ |
| Measured Variables | Mass Flow, Density, Temperature, Volume Flow, Corrected Volume Flow, Reference Density, Concentration |
| Max. Process Pressure | PN 100, Class 600, 63K |
| Mass Flow (gas) | ±0.25 % |