| Ambient Temperature | -50...+80 °C (-58...+176 °F) |
|---|---|
| Sensor Length | Rod Probe: 10 M /Rope Probe: 45 M /Coaxial Probe: 6 M |
| Communication | 4...20 MA HART PROFIBUS PA FOUNDATION Fieldbus |
| Process Pressure/max. Overpressure Limit | Vacuum...400 Bar (Vacuum...5800 Psi) |
| Measuring Principle | Guided Radar |
| Ambient Temperature | -50...+80 °C (-58...+176 °F) |
|---|---|
| Sensor Length | Rod Probe: 10 M /Rope Probe: 45 M /Coaxial Probe: 6 M |
| Communication | 4...20 MA HART PROFIBUS PA FOUNDATION Fieldbus |
| Process Pressure/max. Overpressure Limit | Vacuum...400 Bar (Vacuum...5800 Psi) |
| Measuring Principle | Guided Radar |
| Accuracy | ±0.1% |
|---|---|
| Material | PTFE, PFA, 316L |
| Process Temperature | -80°C...200°C,-112°F...392°F |
| Process Connection | G1/2, G 3/4, G 1, G1 1/2 /NPT 1/2, NPT 3/4, NPT 1", NPT1 1/2 |
| Process Pressure/max. Overpressure Limit | Vacuum ... 100 Bar(Vaccum ... 1450 Psi) |
| Material | Stainless Steel |
|---|---|
| Measuring Principle | Guided Radar |
| Process Pressure/max. Overpressure Limit | Vacuum...400 Bar (Vacuum...5800 Psi) |
| Communication | 4...20 MA HART PROFIBUS PA FOUNDATION Fieldbus |
| Ambient Temperature | -50...+80 °C (-58...+176 °F) |
| Ambient Relative Humidity | ≤93%RH |
|---|---|
| Connection Type | Flange, Thread |
| Control Signal | 4-20mA/0-10V |
| Positioner | Optional |
| Nominal Diameter | DN15–DN600 (½″–24″) |
| Material | Stainless Steel |
|---|---|
| Measuring Principle | Guided Radar |
| Process Pressure/max. Overpressure Limit | Vacuum...400 Bar (Vacuum...5800 Psi) |
| Communication | 4...20 MA HART PROFIBUS PA FOUNDATION Fieldbus |
| Ambient Temperature | -50...+80 °C (-58...+176 °F) |
| Measuring Range | Up To 2000 Psi (137,89 Bar) Differential |
|---|---|
| Wireless Range | Internal Antenna (225 M) |
| Sensitivity | Up To 150:1 |
| Weight | Depends On Specific Instrument |
| Wireless Update Rate | 1 Sec. To 60 Min., User Selectable |
| Working Voltage | DC(18~30)V |
|---|---|
| Conditional | New |
| Maximum Pressure | 200 Barg |
| Protection Level | IP67 |
| Output Accuracy | ±1%F.S |
| Ambient Temperature | -50...+80 °C (-58...+176 °F) |
|---|---|
| Sensor Length | Rod Probe: 10 M /Rope Probe: 45 M /Coaxial Probe: 6 M |
| Communication | 4...20 MA HART PROFIBUS PA FOUNDATION Fieldbus |
| Process Pressure/max. Overpressure Limit | Vacuum...400 Bar (Vacuum...5800 Psi) |
| Measuring Principle | Guided Radar |
| Product Name | Electromagnetic Flowmeter |
|---|---|
| Process Pressure/max. Overpressure Limit | Vacuum...+25 Bar(Vacuum...+362.6 Psi) |
| Measuring Principle | Electromagnetic Flowmeter |
| Communication | 4...20 MA HART |
| Process Temperature | -40...+200 °C (-40...+392 °F) |