| Weight | 3.5KG |
|---|---|
| Maximum Output Torque | 600 Nm |
| Rated Pressure | Maximum 10 Bar |
| Display Screen | LCD Display Screen, Which Can Display Current Position, Power Status, And Other Information |
| Power Supply | 4V DC, 120V AC, Or 240V AC |
| Volume Capacity | Standard Flow |
|---|---|
| Diagnostic | SD Version – Standard Diagnostics |
| Electronics | 4-20mA - Loop Powered |
| Model Number | SVI2-21113111 |
| LCD Interface / Housing Material | With Display And Pushbuttons |
| Volume Capacity | Standard Flow |
|---|---|
| Diagnostic | SD Version – Standard Diagnostics |
| Electronics | 4-20mA - Loop Powered |
| Model Number | SVI2-21113111 |
| LCD Interface / Housing Material | With Display And Pushbuttons |
| Volume Capacity | Standard Flow |
|---|---|
| Diagnostic | SD Version – Standard Diagnostics |
| Electronics | 4-20mA - Loop Powered |
| Model Number | SVI2-21113121 |
| LCD Interface / Housing Material | With Display And Pushbuttons |
| Volume Capacity | Standard Flow |
|---|---|
| Diagnostic | SD Version – Standard Diagnostics |
| Electronics | 4-20mA - Loop Powered |
| Model Number | SVI2-21123111 |
| LCD Interface / Housing Material | With Display And Pushbuttons |
| Volume Capacity | Standard Flow |
|---|---|
| Diagnostic | SD Version – Standard Diagnostics |
| Electronics | 4-20mA - Loop Powered |
| Model Number | SVI2 |
| LCD Interface / Housing Material | With Display And Pushbuttons |
| Input Signal Options | 4-20 MA (analog), HART, FOUNDATION Fieldbus |
|---|---|
| Air Supply Pressure | 3-7 Bar |
| Protection Rating | IP66 |
| Accuracy | ≤ 0.25 % |
| Temperature Range | -52 °C To +85 °C (-62 °F To +185 °F) |
| Operating Temperature Limits | -58°F To 185°F (-50°C To 85°C) |
|---|---|
| Supply Pressure Effect | 0.05% Per Psi |
| Insulation Resistance | Greater Than 10 G Ohms At 50% RH |
| Fast Transient Burst | No Effect At 2 KV |
| Relative Humidity | 10 To 90% Non-condensing |
| Operating Temperature Limits | -58°F To 185°F (-50°C To 85°C) |
|---|---|
| Supply Pressure Effect | 0.05% Per Psi |
| Insulation Resistance | Greater Than 10 G Ohms At 50% RH |
| Fast Transient Burst | No Effect At 2 KV |
| Relative Humidity | 10 To 90% Non-condensing |
| Communication Interface | HART, FOUNDATION Fieldbus, Profibus PA |
|---|---|
| Weight | 3.5KG |
| Power Supply | 4V DC, 120V AC, Or 240V AC |
| Protection Level | IP66 |
| Display Screen | LCD Display Screen, Which Can Display Current Position, Power Status, And Other Information |