| Deadband Adjustment | Adjustable Deadband To Accommodate Different Applications |
|---|---|
| Digital Communication Interface | Optional RS485 Modbus RTU Or FOUNDATION Fieldbus Interface |
| Protection Level | IP66 |
| Output Signal | 4-20mA DC, HART Protocol, Etc |
| Local Display | 4-digit LCD Screen, Which Can Display Current Analog Input Value, Output Value, Set Value, And Device Status Information |
| Operating Temperature Range | -40℃ To 70℃ |
|---|---|
| Digital Communication Interface | Optional RS485 Modbus RTU Or FOUNDATION Fieldbus Interface |
| Protection Level | IP66 |
| Deadband Adjustment | Adjustable Deadband To Accommodate Different Applications |
| Diagnostic Function | It Can Automatically Detect Faults And Device Status, And Provide Warning And Fault Prompt Information |
| Rated Flow Coefficient | Maximum CV Value Of 470 |
|---|---|
| Valve Connection | ISO 5211 Direct Mounting Or VDI/VDE 3845 Mounting With Adapter |
| Material | Aluminum Alloy Or Stainless Steel |
| Valve Travel Range | 10mm To 100mm |
| Zero Point Drift | Less Than 0.1% Of The Maximum Travel Value |
| Diagnostic Functions | Provides Status Reports And Fault Information, Supports Equipment Management And Maintenance |
|---|---|
| Linearity | Less Than 0.5% Of The Maximum Travel Value |
| Zero Point Drift | Less Than 0.1% Of The Maximum Travel Value |
| Material | Aluminum Alloy Or Stainless Steel |
| Suitable Media | Non-corrosive Media Such As Liquids, Gases, And Steam |
| Communication Protocol | 4-20 MA HART |
|---|---|
| Diagnostics | Yes |
| Max Outlet Pressure | 145 Psig |
| Supply Media | Air, Natural Gas, Nitrogen |
| Process Control | Flow, Pressure, Temperature, Level |
| Measurement Range | 0-24 MA DC |
|---|---|
| Display | LCD Display, 2 Lines X 16 Characters |
| Output Resolution | 0.001 MA |
| Battery Life | Approx. 20 Hours Continuous Use At 20 MA Output |
| Accuracy | 0.025% Full Scale |
| Packaging Details | Cardboard box/Wooden crate |
|---|---|
| Delivery Time | 60 days |
| Payment Terms | T/T |
| Supply Ability | Large quantities in stock. |
| Place of Origin | America |
| Communication Protocol | 4-20 MA HART |
|---|---|
| Data Interface | Wired |
| Diagnostics | Yes |
| Input Signal | Electric |
| Max Outlet Pressure | 145 Psig |
| Warranty | 1 YEAR |
|---|---|
| Model Number | D30 |
| Output Signal | 4-20 MA DC |
| Material | Die-cast Aluminum |
| Weight | 1.8 Kg |
| Safety Features | Overvoltage Protection, Reverse Polarity Protection, Short-circuit Protection |
|---|---|
| Programmability | Programmable Through FoxCom Or PC Software |
| Optional Accessories | Pressure Modules, Temperature Sensors, Communication Cables, PC Software |
| Power Output | 24V DC Nominal, 20 MA Max |
| Ramp Function | User-defined Ramp Function With Adjustable Time |