| Media | Gas |
|---|---|
| Signal Range | 4 To 20 MA |
| Sensitivity | ≤0.1 % |
| Direction Of Action | Reversible |
| Degree Of Protection | IP 66/NEMA 4X |
| Accuracy | ± 0.5% |
|---|---|
| Conformity/Linearity | ± 0.5% Full Span |
| Customized Support | OEM, ODM, OBM |
| Operating | -40° F To 185° F (-40° C To 85° C) |
| Repeatability | ± 0.3% Full Span |
| Output Resolution | 0.001 MA |
|---|---|
| Temperature Range | -10°C To 55°C |
| Dimensions | 144 Mm X 80 Mm X 44 Mm |
| Display | LCD Display, 2 Lines X 16 Characters |
| Humidity Range | 0% To 95% (non-condensing) |
| Power Supply | 12-42V DC Power Supply |
|---|---|
| Local Display | 4-digit LCD Screen, Which Can Display Current Analog Input Value, Output Value, Set Value, And Device Status Information |
| Protection Level | IP66 |
| Digital Communication Interface | Optional RS485 Modbus RTU Or FOUNDATION Fieldbus Interface |
| Deadband Adjustment | Adjustable Deadband To Accommodate Different Applications |
| Rated Flow Coefficient | Maximum CV Value Of 470 |
|---|---|
| Valve Connection | ISO 5211 Direct Mounting Or VDI/VDE 3845 Mounting With Adapter |
| Material | Aluminum Alloy Or Stainless Steel |
| Valve Travel Range | 10mm To 100mm |
| Zero Point Drift | Less Than 0.1% Of The Maximum Travel Value |
| Positioning Accuracy | Typically ±0.5% |
|---|---|
| Power Supply Voltage | 24VDC Or 110-240VAC |
| Operating Temperature Range | -40°C To +85°C |
| Mounting | Vertical Or Suspended Mounting Options |
| Accessories | Overload Protection, Manual Operation, Protective Cover, And Transition Plate |
| Operating | -40° F To 185° F (-40° C To 85° C) |
|---|---|
| Name | Masoneilan SVI FF |
| Ambient Humidity | 10 To 95% Non-condensing |
| Customized Support | OEM, ODM, OBM |
| Supply Pressure Effect | 0.05% Per Psi Unit |
| Accuracy | 0.025% Full Scale |
|---|---|
| Output Stability | ±0.01% Of Output Reading Per Hour |
| Communication Interface | HART, FoxCom, RS-232, RS-485 |
| Display | LCD Display, 2 Lines X 16 Characters |
| Weight | Approx. 300g |
| Safety Features | Overvoltage Protection, Reverse Polarity Protection, Short-circuit Protection |
|---|---|
| Temperature Range | -10°C To 55°C |
| Output Resolution | 0.001 MA |
| Ramp Function | User-defined Ramp Function With Adjustable Time |
| Accuracy | 0.01% Full Scale |
| Safety Features | Overvoltage Protection, Reverse Polarity Protection, Short-circuit Protection |
|---|---|
| Programmability | Programmable Through FoxCom Or PC Software |
| Optional Accessories | Pressure Modules, Temperature Sensors, Communication Cables, PC Software |
| Power Output | 24V DC Nominal, 20 MA Max |
| Ramp Function | User-defined Ramp Function With Adjustable Time |