| Product Name | Fisher FIELDVUE DLC3010 DLC3020 DLC3020F Digital Level Controller |
|---|---|
| Brand | FISHER |
| Model | DLC3010 DLC3020 DLC3020F |
| Hazardous Area Classification | Ex H IIC Tx Gb |
| Accuracy | 0.15 |
| Input Signal | 4-20mA DC, 1-5V DC, 0-10V DC, HART Protocol, Etc |
|---|---|
| Protection Level | IP66 |
| Diagnostic Function | It Can Automatically Detect Faults And Device Status, And Provide Warning And Fault Prompt Information |
| Accuracy | Up To 0.075% Under Nominal Conditions |
| Deadband Adjustment | Adjustable Deadband To Accommodate Different Applications |
| Power Supply | 12-42V DC Power Supply |
|---|---|
| Local Display | 4-digit LCD Screen, Which Can Display Current Analog Input Value, Output Value, Set Value, And Device Status Information |
| Protection Level | IP66 |
| Digital Communication Interface | Optional RS485 Modbus RTU Or FOUNDATION Fieldbus Interface |
| Deadband Adjustment | Adjustable Deadband To Accommodate Different Applications |
| Operating Temperature Range | -40℃ To 70℃ |
|---|---|
| Digital Communication Interface | Optional RS485 Modbus RTU Or FOUNDATION Fieldbus Interface |
| Protection Level | IP66 |
| Deadband Adjustment | Adjustable Deadband To Accommodate Different Applications |
| Diagnostic Function | It Can Automatically Detect Faults And Device Status, And Provide Warning And Fault Prompt Information |
| Product Name | Fisher FIELDVUE DLC3010 DLC3020 DLC3020F Digital Level Controller |
|---|---|
| Brand | FISHER |
| Model | DLC3010 DLC3020 DLC3020F |
| Hazardous Area Classification | Ex H IIC Tx Gb |
| Accuracy | 0.15 |
| Turndown | 38:1 |
|---|---|
| Antenna Type | Lens Type |
| Power Supply | 10.5-35V DC (Ex I: 10.5-30V DC) |
| Voltage | AC / DC 220V, AC 380V,etc |
| Output Signal | 4 To 20 MA With HART |
| Rated Flow Coefficient | Maximum CV Value Of 470 |
|---|---|
| Output Signal | 4-20mA, HART, PROFIBUS PA Or FOUNDATION Fieldbus |
| Valve Position Feedback | Provides Digital Position Feedback Through Hall Sensors Or Analog Position Feedback Through Potentiometers |
| Protection Rating | IP66/67 |
| Valve Travel Range | 10mm To 100mm |
| Set Point | 4 To 20 MA |
|---|---|
| Valve Travel | 3.6 To 300 Mm |
| Opening Angle | 24 To 100° |
| Material | Steel |
| Communication | HART® Field Communication Protocol |
| Position Control | Throttling Control, On/Off |
|---|---|
| Mounting Type | Integral Mounted |
| Shell Material | Industrial Aluminum Housing |
| Communication Protocol | HART, 4-20mA Analog |
| Product | Digital Positioner |
| Mounting Type | Direct Or Remote Mounting On Rotary Or Linear Control Valves |
|---|---|
| Communication Protocol | HART (Highway Addressable Remote Transducer) |
| Input Signal | 4-20 MA DC |
| Air Supply Pressure | 1.4 To 7 Bar (20 To 100 Psi) |
| Air Consumption | Approx. 0.4 Kg/h (at 1.4 Bar) |