| Position Control | Throttling Control, On/Off |
|---|---|
| Max Outlet Pressure | 145 Psig |
| Condition | New And Origin |
| Certifications | CSA, FM, ATEX, IECEx, CUTR, Peso, KGS, INMETRO, NEPSI, TIIS, Natural Gas Certified |
| Warranty | One Year |
| Position Control | Throttling Control, On/Off |
|---|---|
| Max Outlet Pressure | 145 Psig |
| Condition | New And Origin |
| Certifications | CSA, FM, ATEX, IECEx, CUTR, Peso, KGS, INMETRO, NEPSI, TIIS, Natural Gas Certified |
| Warranty | One Year |
| Weight | 3.5 Kg |
|---|---|
| Voltage Supply (maximum) | 30 VDC |
| Minimum Required Operating Current | 3.6 MA |
| Repeatability | < 0.25% |
| Input Signal Range | 4 - 20 MA HART |
| Supply Pressure | Beta 5: 1.4-7 Bar (20-100 Psi) /Beta 7: 1.4-10 Bar (20-150 Psi) |
|---|---|
| Ambient Temperature | Standard: -40°C To +85°C (-40°F To +185°F) |
| Communication | HART 5/7, FF Foundation Fieldbus (Optional) |
| Application Industry | Oil & Gas, Chemical, Power Industry Valve Control |
| Ingress Protection (IP) | IP66/67 (Dust/Waterproof) |
| Mounting Type | Direct Or Remote Mounting On Rotary Or Linear Control Valves |
|---|---|
| Communication Protocol | HART (Highway Addressable Remote Transducer) |
| Input Signal | 4-20 MA DC |
| Air Supply Pressure | 1.4 To 7 Bar (20 To 100 Psi) |
| Air Consumption | Approx. 0.4 Kg/h (at 1.4 Bar) |
| Housing Material | Low Copper Chromated Aluminum (ASTM A360) |
|---|---|
| Protection Rating | IP66 / NEMA 4X |
| Weight | 2 Kg (4.5 Lb) |
| Input Power/Signal | 3.2-24 MA; Compliance: 9 VDC At 20 MA, 11 VDC At 4 MA |
| Optional Outputs | Two Solid-state Switches (1A/30 VDC); 4-20 MA Position Retransmit |
| Warranty | 3 Years |
|---|---|
| Model Number | DVC2000 |
| Input Signal | Electric |
| Mounting Type | Integral Mounted |
| Process Control | Flow, Pressure, Temperature, Level |
| Safety Features | Overvoltage Protection, Reverse Polarity Protection, Short-circuit Protection |
|---|---|
| Ramp Function | User-defined Ramp Function With Adjustable Time |
| Optional Accessories | Pressure Modules, Temperature Sensors, Communication Cables, PC Software |
| Step Function | 25% Step, 100% Step, User-defined Step |
| Certifications | CE, CSA, FM, ATEX, IECEx, GOST-R |
| Supply Pressure | 20 - 100 Psi (1.4 – 7 Bar) |
|---|---|
| Type | Digital Valve Positioner |
| Shell Material | Industrial Aluminum Housing |
| Model Number | SVi1000 |
| MCommunication Platform | HART |
| Operating Temperature | Standard Temperature, High Temperature |
|---|---|
| Sensitivity | ≤0.1 % |
| Valve Travel | 3.6 To 300 Mm |
| COMMUNICATION | HART® |
| Hysteresis | ≤0.3 % |