| Process Control | Flow, Pressure, Temperature, Level |
|---|---|
| Diagnostics | Yes |
| Power Source | Local |
| Area Classification | Explosion Proof, Intrinsically Safe, FISCO, Type N, Flame Proof, Non-incendive For FM |
| Communication Protocol | 4-20 MA HART |
| Operating Temperature Range | -40℃ To 70℃ |
|---|---|
| Digital Communication Interface | Optional RS485 Modbus RTU Or FOUNDATION Fieldbus Interface |
| Protection Level | IP66 |
| Deadband Adjustment | Adjustable Deadband To Accommodate Different Applications |
| Diagnostic Function | It Can Automatically Detect Faults And Device Status, And Provide Warning And Fault Prompt Information |
| Rated Flow Coefficient | Maximum CV Value Of 470 |
|---|---|
| Output Signal | 4-20mA, HART, PROFIBUS PA Or FOUNDATION Fieldbus |
| Valve Position Feedback | Provides Digital Position Feedback Through Hall Sensors Or Analog Position Feedback Through Potentiometers |
| Protection Rating | IP66/67 |
| Valve Travel Range | 10mm To 100mm |
| Communication Interface | HART, FOUNDATION Fieldbus, Profibus PA |
|---|---|
| Action Time | 0.3-30 Seconds |
| Display Screen | LCD Display Screen, Which Can Display Current Position, Power Status, And Other Information |
| Installation Method | Bracket Or Flange Installation |
| Maximum Output Torque | 600 Nm |
| Type | Electromagnetic Meters |
|---|---|
| Connectivity | Flange |
| Communication Output | RS485, Modbus-RTU Communication Protocol |
| Accuracy | +/-0.5% |
| Ambient Temperature | (-10~55)℃ |
| Material | Stainless Steel |
|---|---|
| Max. Process Pressure | PN 40, Class 150, 20K |
| Inputs | Status Input 4-20 MA Input |
| Degree Of Protection | IP66/67, Type 4X Enclosure IP69 |
| Medium Temperature Range | -20 To +150 °C (-4 To +302 °F) |
| Max Outlet Pressure | 101 Psig |
|---|---|
| Data Interface | Wired |
| Mounting Type | Integral Mounted |
| Communication Protocol | HART, 4-20mA Analog |
| Operating Temperature | Standard Temperature, High Temperature |
| Minimum Current Signal | 3.2mA |
|---|---|
| Pressure | High Pressure |
| Protection Level | IP54 |
| Maximum Voltage | 30.0 VDC |
| Weight | Aluminum3.5 Kg |
| Type | Electromagnetic Meters |
|---|---|
| Connectivity | Flange |
| Communication Output | RS485, Modbus-RTU Communication Protocol |
| Accuracy | +/-0.5% |
| Ambient Temperature | (-10~55)℃ |
| Accessories | Carrying Case, Test Leads, Alligator Clips, User Manual, Certificate Of Calibration |
|---|---|
| Power Output | 24V DC Nominal, 30 MA Max |
| Output Resolution | 0.001 MA |
| Power Supply | 9V DC 4 X 1.5V AA Batteries Or Rechargeable Battery |
| Display | LCD Display, 2 Lines X 16 Characters |