| Medium Temperature Range | -40 To +150 °C (-40 To +302 °F) |
|---|---|
| Accuracy | ±0.15 % |
| Measurement Range | 0 To 180 000 Kg/h (0 To 6615 Lb/min) |
| Medium | Liquid, Gas |
| Liquid, Gas | PN 100, Class 600, 63K |
| Process Connections | Threaded, Flange, Hygienic, Remote Seal |
|---|---|
| Wireless Range | Internal Antenna (225 M) |
| Rangedown | Up To 150:1 |
| Condition | New |
| Fluid Media | Air, Water, Oil, Gas |
| Output Modules | P/P (3-15 Psi) Or I/P (4-20 MA; Optional 10-50 MA) |
|---|---|
| Supply Pressure Tolerance | Up To 150 Psi Without External Regulator |
| Shock & Vibration Handling | Up To 2 G And 500 Hz Vibration Frequency Support |
| Signal Split Range | 2-, 3-, Or 4-way Split Range |
| Air Consumption | ~0.25 SCFM (steady State) / Up To 0.31 SCFM (I/P Module) |
| Product Name | Sipos G7 Electric Actuator For Fisher EWT EZ Control Valve And Valve Actuator |
|---|---|
| Brand | Sipos |
| Model | G7 |
| Matrial | Alloy/Steel |
| Valve Style | Actuator |
| Product Name | Fisher 4200 4210 4211 Electronic Position Transmitter |
|---|---|
| Brand | FISHER |
| Model | Fisher 4200 4210 4211 |
| Hazardous Area Classification | Ex H IIC Tx Gb |
| Accuracy | 0.15 |
| Condition | New |
|---|---|
| Model Number | SVI II |
| Air Supply Pressure | Single-Acting(1.4 To 6.9 Bar), Double-Acting(1.4 To 10.3 Bar) |
| Pneumatics Action | Single Or Double Acting, Fail Safe,Rotary And Linear |
| Diagnostics | Standard Diagnostics,Advanced Diagnostics |
| Type | Digital Valve Positioner |
|---|---|
| Signal - Supply | 4-20 MA Control Signal/No External Power Required |
| Condition | New And Origin |
| Case/Cover | Low Copper And Chromated Aluminum, ASTM A360 |
| Certifications | ATEX, FM, IEC, And CSA Approvals. Intrinsically Safe And Non-incendive (energy Limited) |
| Zero Point Drift | Less Than 0.1% Of The Maximum Travel Value |
|---|---|
| Valve Travel Range | 10mm To 100mm |
| Valve Connection | ISO 5211 Direct Mounting Or VDI/VDE 3845 Mounting With Adapter |
| Protection Rating | IP66/67 |
| Linearity | Less Than 0.5% Of The Maximum Travel Value |
| Measurement Range | Liquids And Gases |
|---|---|
| Medium | Liquids, Gases |
| Warranty | 1 Year |
| Measurement Principle | Coriolis |
| Ultra-low And High-temperature Media | -200...+400°C |
| Air Con | 0.082 To 0.637 Nm3/h @ 4.1 Bar |
|---|---|
| Temp | -52°C To 85°C (-61.6°F To 185°F) |
| Materials | Copper Free Aluminum, Stainless Steel |
| Repeatability | ≤0.25% |
| Air Cap | 30.6 Nm3/h @ 4.1 Bar (18 SCFM @ 60 Psi) |