| Payment Terms | T/T,L/C |
|---|---|
| Supply Ability | N/A |
| Place of Origin | China |
| Brand Name | Rosemount |
| Model Number | 3144P |
| Measuring Range | 100 Mbar To 40 Bar (absolute/gauge) |
|---|---|
| Medium Temperature | -196 To 425 °C |
| Calibration | Single Calibration |
| Ingress Protection | IP66/67 |
| Storage Function | 1000 Record Can Be Saved |
| Ambient Temperature | -50 °C...+70 °C (-58 °F...+158 °F) |
|---|---|
| Process Temperature | -50 °C...+150 °C (-58 °F...+302 °F) |
| Process Pressure / Max. Overpressure Limit | Vacuum...100 Bar |
| Min. Density Of Medium | 0.5g/cm³(0.4g/cm³ Optional) |
| Main Wetted Parts | 316L / Alloy |
| Actuator Compatibility | Single-acting (spring-return) & Double-acting |
|---|---|
| Calibration | Field Adjustable (zero, Span, Action) |
| Air Consumption (Steady State) | Low, Typically < 0.1 SCFM |
| Brand / Manufacturer | Masoneilan |
| Output Air Pressure | 0 To 100% Of Supply Pressure |
| Leakage Rating | ANSI Class IV-VI |
|---|---|
| Display Type | LCD Or LED Display |
| Communication Interface | Depends On Specific Instrument |
| Test Hole | 4 Holes |
| Material | Stainless Steel, Aluminum, Etc. |
| Product Name | Rosemount 5600 Radar Level Transmitter |
|---|---|
| Accuracy | ±3 Mm Or ±0.03% Of Full Scale |
| Material | Stainless Steel/PTFE/PP |
| Pressure Range | Up To 40 Bar |
| Operating Temperature Range | -40°C To +200°C |
| Mounting | Direct Mount On Linear (stem) Or Rotary (ISO 5211) Actuators |
|---|---|
| Input/Output Connections | Conduit Entries Or Integral Connectors |
| Enclosure Rating | Minimum IP66 / NEMA 4X; Explosion-proof Options Available |
| Linearity | ±0.5% To ±2.0% Of Span |
| Output Air Pressure | 0 To 100% Of Supply Pressure |
| Calibration | Field Adjustable (zero, Span, Action) |
|---|---|
| Materials (Housing) | Aluminum, Stainless Steel, Or Coated Cast Iron |
| Air Consumption (Steady State) | Low, Typically < 0.1 SCFM |
| Process/Valve Temperature Range | -196°C To +450°C |
| Input Signal (Electro-Pneumatic) | 4-20 MA DC (Standard) |
| Load Impedance | ≤ 8.2 V |
|---|---|
| Hysteresis | ≤ 0.3 % |
| Sensitivity | ≤ 0.1 % |
| Permissible Ambient Temperature | -20 To +80 °C, With Metal Cable Gland -40 To +80 °C |
| Output Signal | 4 To 20 MA |
| Load Impedance | ≤ 8.2 V |
|---|---|
| Minimum Current | 3.6 MA For Display, 3.8 MA For Operation |
| Permissible Ambient Temperature | -20 To +80 °C, With Metal Cable Gland -40 To +80 °C |
| Output Signal | 4 To 20 MA |
| Supply Voltage | 12 To 30 V DC |