Input Signal | 4-20mA DC, 1-5V DC, 0-10V DC, HART Protocol, Etc |
---|---|
Protection Level | IP66 |
Diagnostic Function | It Can Automatically Detect Faults And Device Status, And Provide Warning And Fault Prompt Information |
Accuracy | Up To 0.075% Under Nominal Conditions |
Deadband Adjustment | Adjustable Deadband To Accommodate Different Applications |
Power Supply | 12-42V DC Power Supply |
---|---|
Local Display | 4-digit LCD Screen, Which Can Display Current Analog Input Value, Output Value, Set Value, And Device Status Information |
Protection Level | IP66 |
Digital Communication Interface | Optional RS485 Modbus RTU Or FOUNDATION Fieldbus Interface |
Deadband Adjustment | Adjustable Deadband To Accommodate Different Applications |
Protection Level | IP66 |
---|---|
Deadband Adjustment | Adjustable Deadband To Accommodate Different Applications |
Diagnostic Function | It Can Automatically Detect Faults And Device Status, And Provide Warning And Fault Prompt Information |
Local Display | 4-digit LCD Screen, Which Can Display Current Analog Input Value, Output Value, Set Value, And Device Status Information |
Power Supply | 12-42V DC Power Supply |
Communication Interface | HART, FOUNDATION Fieldbus, Profibus PA |
---|---|
Action Time | 0.3-30 Seconds |
Display Screen | LCD Display Screen, Which Can Display Current Position, Power Status, And Other Information |
Installation Method | Bracket Or Flange Installation |
Maximum Output Torque | 600 Nm |
Product Name | Azbil Smart Pneumatic Positioners AVP300/301/302 Positioner |
---|---|
Brand | Azbil |
Model | AVP300/301/302 |
Matrial | Alloy/Steel |
Valve Style | Positioner |
Operating Temperature Range | -40℃ To 70℃ |
---|---|
Digital Communication Interface | Optional RS485 Modbus RTU Or FOUNDATION Fieldbus Interface |
Protection Level | IP66 |
Deadband Adjustment | Adjustable Deadband To Accommodate Different Applications |
Diagnostic Function | It Can Automatically Detect Faults And Device Status, And Provide Warning And Fault Prompt Information |
Rated Flow Coefficient | Maximum CV Value Of 470 |
---|---|
Output Signal | 4-20mA, HART, PROFIBUS PA Or FOUNDATION Fieldbus |
Valve Position Feedback | Provides Digital Position Feedback Through Hall Sensors Or Analog Position Feedback Through Potentiometers |
Protection Rating | IP66/67 |
Valve Travel Range | 10mm To 100mm |
Maximum Output Torque | 600 Nm |
---|---|
Ambient Temperature | -20℃ ~ +70℃ |
Protection Level | IP66 |
Communication Interface | HART, FOUNDATION Fieldbus, Profibus PA |
Installation Method | Bracket Or Flange Installation |
Humidity Range | 0% To 95% (non-condensing) |
---|---|
Communication Interface | HART, FoxCom, RS-232, RS-485 |
Output Stability | ±0.01% Of Output Reading Per Hour |
Optional Accessories | Pressure Modules, Temperature Sensors, Communication Cables, PC Software |
Battery Life | Approx. 20 Hours Continuous Use At 20 MA Output |
Model Number | SVI2-21123121 |
---|---|
Communication Protocols | HART Version 7 Digitally Enhanced Fieldbus |
Type | Valve Locator |
Packaging Specifications | 30 * 45 * 40 |