| Output Modules | P/P (3-15 Psi) Or I/P (4-20 MA; Optional 10-50 MA) |
|---|---|
| Supply Pressure Tolerance | Up To 150 Psi Without External Regulator |
| Shock & Vibration Handling | Up To 2 G And 500 Hz Vibration Frequency Support |
| Signal Split Range | 2-, 3-, Or 4-way Split Range |
| Air Consumption | ~0.25 SCFM (steady State) / Up To 0.31 SCFM (I/P Module) |
| Condition | New |
|---|---|
| Model Number | SVI II |
| Air Supply Pressure | Single-Acting(1.4 To 6.9 Bar), Double-Acting(1.4 To 10.3 Bar) |
| Pneumatics Action | Single Or Double Acting, Fail Safe,Rotary And Linear |
| Diagnostics | Standard Diagnostics,Advanced Diagnostics |
| Product Name | Fisher 4200 4210 4211 Electronic Position Transmitter |
|---|---|
| Brand | FISHER |
| Model | Fisher 4200 4210 4211 |
| Hazardous Area Classification | Ex H IIC Tx Gb |
| Accuracy | 0.15 |
| Type | Digital Valve Positioner |
|---|---|
| Signal - Supply | 4-20 MA Control Signal/No External Power Required |
| Condition | New And Origin |
| Case/Cover | Low Copper And Chromated Aluminum, ASTM A360 |
| Certifications | ATEX, FM, IEC, And CSA Approvals. Intrinsically Safe And Non-incendive (energy Limited) |
| Zero Point Drift | Less Than 0.1% Of The Maximum Travel Value |
|---|---|
| Valve Travel Range | 10mm To 100mm |
| Valve Connection | ISO 5211 Direct Mounting Or VDI/VDE 3845 Mounting With Adapter |
| Protection Rating | IP66/67 |
| Linearity | Less Than 0.5% Of The Maximum Travel Value |
| Measurement Range | Liquids And Gases |
|---|---|
| Medium | Liquids, Gases |
| Warranty | 1 Year |
| Measurement Principle | Coriolis |
| Ultra-low And High-temperature Media | -200...+400°C |
| Air Con | 0.082 To 0.637 Nm3/h @ 4.1 Bar |
|---|---|
| Temp | -52°C To 85°C (-61.6°F To 185°F) |
| Materials | Copper Free Aluminum, Stainless Steel |
| Repeatability | ≤0.25% |
| Air Cap | 30.6 Nm3/h @ 4.1 Bar (18 SCFM @ 60 Psi) |
| Delivery Time | 90 work days |
|---|---|
| Payment Terms | T/T |
| Brand Name | Rosemount |
| Model Number | 3051 |
| Rated Operating Pressure | Up To 16 Bar |
|---|---|
| Diagnostic Functions | Provides Status Reports And Fault Information, Supports Equipment Management And Maintenance |
| Suitable Media | Non-corrosive Media Such As Liquids, Gases, And Steam |
| Linearity | Less Than 0.5% Of The Maximum Travel Value |
| Operating Temperature Range | -40°C To +85°C |
| Product Name | OPTISWIRL 4200 Vortex Flowmeter |
|---|---|
| Medium | Liquid, Gas, Steam |
| Process Pressure | Max. 100 Barg/ 1450 Psig |
| Measurement Principle | Vortex |
| Connectivity | Flange And Thread |