| Sensitivity | Up To 150:1 |
|---|---|
| Weight | Depends On Specific Instrument |
| Wetted Material | Stainless Steel; 316 / 316L And CF3M |
| Wireless Update Rate | 1 Sec. To 60 Min., User Selectable |
| Measuring Range | Up To 2000 Psi (137,89 Bar) Differential |
| Product Name | Azbil Smart Pneumatic Positioners AVP300/301/302 Positioner |
|---|---|
| Brand | Azbil |
| Model | AVP300/301/302 |
| Matrial | Alloy/Steel |
| Valve Style | Positioner |
| Sensitivity | Up To 150:1 |
|---|---|
| Weight | Depends On Specific Instrument |
| Wetted Material | Stainless Steel; 316 / 316L And CF3M |
| Wireless Update Rate | 1 Sec. To 60 Min., User Selectable |
| Measuring Range | Up To 2000 Psi (137,89 Bar) Differential |
| Process Temperature | -40°C To +150°C |
|---|---|
| Protection Class | IP68 (standard) |
| Output Signal | 4-20mA+HART, Optional Profibus PA/FF/Profinet |
| Power Supply | 10.5-35V DC (Ex I: 10.5-30V DC) |
| Accuracy | ±0.075% (standard), ±0.025% (Platinum) |
| Output / Protocol | 4-20 MA With HART; FOUNDATION Fieldbus; PROFIBUS PA |
|---|---|
| Display/Interface | LCD Display, LCD Display With Local Operator Interface (LOI), Or LED |
| IP Rating | IP66 |
| Mounting / Housing | Head Mount (DIN A), Field Mount, Rail Mount |
| Diagnostics | Yes |
| Brand | FEEJOY |
|---|---|
| Model | FJM-L |
| Density | ≥0.5 G/cm³ |
| Rated Pressure | ≤5.0 MPa |
| Rated Temperature | -40...+200°C |
| Product Name | Electromagnetic Flowmeter |
|---|---|
| Process Pressure/max. Overpressure Limit | Vacuum...+25 Bar(Vacuum...+362.6 Psi) |
| Measuring Principle | Electromagnetic Flowmeter |
| Communication | 4...20 MA HART |
| Process Temperature | -40...+200 °C (-40...+392 °F) |
| Material | Stainless Steel |
|---|---|
| Measuring Principle | Guided Radar |
| Process Pressure/max. Overpressure Limit | Vacuum...400 Bar (Vacuum...5800 Psi) |
| Communication | 4...20 MA HART PROFIBUS PA FOUNDATION Fieldbus |
| Ambient Temperature | -50...+80 °C (-58...+176 °F) |
| Ambient Temperature | -50...+80 °C (-58...+176 °F) |
|---|---|
| Sensor Length | Rod Probe: 10 M /Rope Probe: 45 M /Coaxial Probe: 6 M |
| Communication | 4...20 MA HART PROFIBUS PA FOUNDATION Fieldbus |
| Process Pressure/max. Overpressure Limit | Vacuum...400 Bar (Vacuum...5800 Psi) |
| Measuring Principle | Guided Radar |
| Valve Type | Linear Or Rotary Motion Control Valve |
|---|---|
| Repeatability | ± 0.3 Percent Full Span |
| Required Terminal Voltage | 9 VDC At 20mA |
| Power Supply | 4-20mA |
| Minimum Current Signal | 3.2mA |