| Voltage | 110V/220V |
|---|---|
| Port | Main Ports In China |
| Communication Protocol | HART |
| Actuator Area | 160 Cm² · 320 Cm² |
| Connectin | 1/4 NPT |
| Min./ Max.Current | Min./ Max.Current |
|---|---|
| Air Consumption | Sup= 1.4~6 Bar |
| Protection Class | IP66 |
| Body Material | Aluminium |
| Air Supply Pressure | 1.4 - 7.0 Bar ( 20 - 100 Psi ) |
| Min./ Max.Current | Min./ Max.Current |
|---|---|
| Air Consumption | Sup= 1.4~6 Bar |
| Protection Class | IP66 |
| Body Material | Aluminium |
| Air Supply Pressure | 1.4 - 7.0 Bar ( 20 - 100 Psi ) |
| Temperature Range | -40 ... +85 °C / -40 ... +185 °F, Standard Version |
|---|---|
| Protection Class | IP66 / NEMA 4X Enclosure |
| Diagnostics | Yes |
| Communication | HART, FOUNDATION Fieldbus, Profibus PA |
| Packaging Details | Wooden box + protection |
| Maximum Hysteresis | 0.3 % |
|---|---|
| Stroke Range | 8-260 Mm |
| Model Number | SRD991 |
| Input Pressure | 1.4-6 Bar |
| Linearity | < 0.4 % Of The Travel Span |
| Safety Features | Overvoltage Protection, Reverse Polarity Protection, Short-circuit Protection |
|---|---|
| Temperature Range | -10°C To 55°C |
| Output Resolution | 0.001 MA |
| Ramp Function | User-defined Ramp Function With Adjustable Time |
| Accuracy | 0.01% Full Scale |
| Deadband Adjustment | Adjustable Deadband To Accommodate Different Applications |
|---|---|
| Digital Communication Interface | Optional RS485 Modbus RTU Or FOUNDATION Fieldbus Interface |
| Protection Level | IP66 |
| Output Signal | 4-20mA DC, HART Protocol, Etc |
| Local Display | 4-digit LCD Screen, Which Can Display Current Analog Input Value, Output Value, Set Value, And Device Status Information |
| Communication Interface | HART, FOUNDATION Fieldbus, Profibus PA |
|---|---|
| Weight | 3.5KG |
| Power Supply | 4V DC, 120V AC, Or 240V AC |
| Protection Level | IP66 |
| Display Screen | LCD Display Screen, Which Can Display Current Position, Power Status, And Other Information |
| Display Screen | LCD Display Screen, Which Can Display Current Position, Power Status, And Other Information |
|---|---|
| Ambient Temperature | -20℃ ~ +70℃ |
| Maximum Output Torque | 600 Nm |
| Installation Method | Bracket Or Flange Installation |
| Power Supply | 4V DC, 120V AC, Or 240V AC |
| Communication Interface | HART, FOUNDATION Fieldbus, Profibus PA |
|---|---|
| Action Time | 0.3-30 Seconds |
| Display Screen | LCD Display Screen, Which Can Display Current Position, Power Status, And Other Information |
| Installation Method | Bracket Or Flange Installation |
| Maximum Output Torque | 600 Nm |