| Temperature | -40...+240°C / -40...+465°F |
|---|---|
| Ingress Protection | IP 66/67 |
| Pressure | Max. 100 Bar / 1450 Psi |
| Repeatability | ±0.1% Of Measured Value |
| Measurement Range | 4...20 MA (max. 20.8 MA) + HART Protocol |
| Process Temperature | 0°C To +70°C |
|---|---|
| Measurement Range | 0.03 To 12 M/s |
| Accuracy | ±0.25 % Of Reading ±0.1 % Fulll Scale (for Powered Devices) |
| Material | Body In Painted Steel / Optionally Stainless Steel |
| Packaging Details | As required |
| Weight | 10-20KG |
|---|---|
| Material Certificates | 3.1 Material NACE MR0175/MR0103, PMI; Welding Test Acc. To EN ISO, ASME, NORSOK |
| Product Safety | CE, C-tick, EAC Marking |
| Functional Safety | Functional Safety According To IEC 61508, Applicable In Safety-relevant Applications In Accordance With IEC 61511 |
| Model | Proline Promass F 200 |
| Approval; Transmitter + Sensor | ATEX+IECEx; Z0/1, Z21, Ex De, IIC/IIIC |
|---|---|
| Power Supply | DC 24V |
| Output; Input 1 | Modbus RS485 |
| Output; Input 2 | 4-20mA |
| Output; Input 3 | Configurable I/O Default Off |
| Weight | 10-20KG |
|---|---|
| Inputs | Status Input 4-20 MA Input |
| Ambient Temperature Range | Standard: –40 To +60 °C (–40 To +140 °F) Option: –60 To +60 °C (–76 To +140 °F) |
| Type | Coriolis Flowmeter |
| Max. Process Pressure | PN 100, Class 600, 63K |
| Type | Coriolis Meters |
|---|---|
| Material | Stainless Steel |
| Model Number | Proline Promass E 300 |
| Medium Temperature Range | -40 To +150 °C (-40 To +302 °F) |
| Inputs | Status Input 4-20 MA Input |
| Product Name | Electromagnetic Flowmeter |
|---|---|
| Process Pressure/max. Overpressure Limit | Vacuum...+25 Bar(Vacuum...+362.6 Psi) |
| Measuring Principle | Electromagnetic Flowmeter |
| Communication | 4...20 MA HART |
| Process Temperature | -40...+200 °C (-40...+392 °F) |
| Product Name | Endress+Hauser Transmitte FMU90 Ultrasonic Flowmeter For Top Hat Rail |
|---|---|
| Measuring Principle | Ultrasonic |
| Protection Class | IP 66 / NEMA 4x |
| Supply | 90-253 VAC/10.5 -32 VDC/ Up To 2x 4-20mA HART /Profibus DP |
| Accuracy | +/- 2mm + 0.17% Of Measured Distance |
| Measurement Range | 0.1...20 M/s (200:1) |
|---|---|
| Process Temperature | -40...+200°C/ -40...+392°F |
| Digital Outputs | FOUNDATION Fieldbus, HART, Profibus-PA, Profibus-DP, Modbus RTU |
| Analogue Outputs | 4...20 MA |
| Measured Media | Liquids |
| Warranty | Up To 5-year Limited Warranty |
|---|---|
| Resolution | High Resolution |
| Stability | ±1.0%FS/30min |
| Nominal Diameter | DN15–DN600 (½″–24″) |
| Temperature Compensation | (0.1 To 60.0)oC (auto Or Manual) |