| Safety Features | Overvoltage Protection, Reverse Polarity Protection, Short-circuit Protection |
|---|---|
| Programmability | Programmable Through FoxCom Or PC Software |
| Optional Accessories | Pressure Modules, Temperature Sensors, Communication Cables, PC Software |
| Power Output | 24V DC Nominal, 20 MA Max |
| Ramp Function | User-defined Ramp Function With Adjustable Time |
| Humidity Range | 0% To 95% (non-condensing) |
|---|---|
| Communication Interface | HART, FoxCom, RS-232, RS-485 |
| Output Stability | ±0.01% Of Output Reading Per Hour |
| Optional Accessories | Pressure Modules, Temperature Sensors, Communication Cables, PC Software |
| Battery Life | Approx. 20 Hours Continuous Use At 20 MA Output |
| Sensing Principle | Zirconia (in-situ Probe) |
|---|---|
| Typical Applications | Refinery Fired Heaters / Reformer / Cracking Furnaces |
| Output Range | From 0-1% To 0-100% |
| Contact Rating | 0.5A, 30V, 10VA Max. Non-inductive Load, AC Or DC |
| Enclosure | IP65 (NEMA 4X) |
| Accuracy | 0.01% Full Scale |
|---|---|
| Certifications | CE, CSA, FM, ATEX, IECEx, GOST-R |
| Optional Accessories | Pressure Modules, Temperature Sensors, Communication Cables, PC Software |
| Power Supply | 9V DC 4 X 1.5V AA Batteries Or Rechargeable Battery |
| Output Resolution | 0.001 MA |
| Process Control | Flow, Pressure, Temperature, Level |
|---|---|
| Diagnostics | Yes |
| Power Source | Local |
| Area Classification | Explosion Proof, Intrinsically Safe, FISCO, Type N, Flame Proof, Non-incendive For FM |
| Communication Protocol | 4-20 MA HART |
| Battery Life | Approx. 30 Hours Continuous Use At 20 MA Output |
|---|---|
| Accessories | Carrying Case, Test Leads, Alligator Clips, User Manual, Certificate Of Calibration |
| Power Output | 24V DC Nominal, 30 MA Max |
| Optional Accessories | Pressure Modules, Temperature Sensors, Communication Cables, PC Software |
| Power Supply | 9V DC 4 X 1.5V AA Batteries Or Rechargeable Battery |
| Mounting | Horizontal/vertical/in-line |
|---|---|
| Sealing Rating | ANSI Class 150/300/600 |
| Connection | Flange/Threaded/Butt-weld |
| Explosion-proof Certification | ATEX Zone 1/IECEx |
| Control Signal | 4-20mA/Modbus/HART |
| Precision | High Precision |
|---|---|
| Weight | Depends On Specific Instrument |
| Sensitivity | Up To 150:1 |
| Wetted Material | Stainless Steel; 316 / 316L And CF3M |
| Power Module Life | Up To 10-year Life, Field Replaceable (order Separately) |
| Degree Of Protection | IP66 |
|---|---|
| Resolution | High Resolution |
| Warranty | Up To 5-year Limited Warranty |
| Connection Type | Threaded/Flanged |
| Pressure | 2.5-6.4Mpa |
| Measuring Range | Up To 2000 Psi (137,89 Bar) Differential |
|---|---|
| Temperature Range | -200°C To +850°C |
| Sensitivity | Up To 150:1 |
| Flange Options | ANSI Class 150 To 1500 |
| Weight | Depends On Specific Instrument |