| Safety Features | Overvoltage Protection, Reverse Polarity Protection, Short-circuit Protection |
|---|---|
| Programmability | Programmable Through FoxCom Or PC Software |
| Optional Accessories | Pressure Modules, Temperature Sensors, Communication Cables, PC Software |
| Power Output | 24V DC Nominal, 20 MA Max |
| Ramp Function | User-defined Ramp Function With Adjustable Time |
| Measurement Range | 0-24 MA DC |
|---|---|
| Display | LCD Display, 2 Lines X 16 Characters |
| Output Resolution | 0.001 MA |
| Battery Life | Approx. 20 Hours Continuous Use At 20 MA Output |
| Accuracy | 0.025% Full Scale |
| Output Resolution | 0.001 MA |
|---|---|
| Temperature Range | -10°C To 55°C |
| Dimensions | 144 Mm X 80 Mm X 44 Mm |
| Display | LCD Display, 2 Lines X 16 Characters |
| Humidity Range | 0% To 95% (non-condensing) |
| Safety Features | Overvoltage Protection, Reverse Polarity Protection, Short-circuit Protection |
|---|---|
| Temperature Range | -10°C To 55°C |
| Output Resolution | 0.001 MA |
| Ramp Function | User-defined Ramp Function With Adjustable Time |
| Accuracy | 0.01% Full Scale |
| Accessories | Carrying Case, Test Leads, Alligator Clips, User Manual, Certificate Of Calibration |
|---|---|
| Power Output | 24V DC Nominal, 30 MA Max |
| Output Resolution | 0.001 MA |
| Power Supply | 9V DC 4 X 1.5V AA Batteries Or Rechargeable Battery |
| Display | LCD Display, 2 Lines X 16 Characters |
| Battery Life | Approx. 30 Hours Continuous Use At 20 MA Output |
|---|---|
| Accessories | Carrying Case, Test Leads, Alligator Clips, User Manual, Certificate Of Calibration |
| Power Output | 24V DC Nominal, 30 MA Max |
| Optional Accessories | Pressure Modules, Temperature Sensors, Communication Cables, PC Software |
| Power Supply | 9V DC 4 X 1.5V AA Batteries Or Rechargeable Battery |
| Type Designation | Safety Shutdown Valve Or Isolating Valve |
|---|---|
| Model | RZD - X |
| Scope | Sizes: 2" - 72" ;Ratings: ASME 150 - 2500 Or API 3000 - 10000;Higher Pressure Ratings Upon Request |
| In Preference To | Ball Valve;Plug Valve;Gate Valve |
| Typical Applications | Severe-duty On-off (upstream);Quick-acting On-off (HIPPS, ESD);Flow Line And Header On-off;Switching Valve (mol Sieve) |
| Zero Point Drift | Less Than 0.1% Of The Maximum Travel Value |
|---|---|
| Valve Travel Range | 10mm To 100mm |
| Valve Connection | ISO 5211 Direct Mounting Or VDI/VDE 3845 Mounting With Adapter |
| Protection Rating | IP66/67 |
| Linearity | Less Than 0.5% Of The Maximum Travel Value |
| Rated Flow Coefficient | Maximum CV Value Of 470 |
|---|---|
| Output Signal | 4-20mA, HART, PROFIBUS PA Or FOUNDATION Fieldbus |
| Valve Position Feedback | Provides Digital Position Feedback Through Hall Sensors Or Analog Position Feedback Through Potentiometers |
| Protection Rating | IP66/67 |
| Valve Travel Range | 10mm To 100mm |
| Material | Casting |
|---|---|
| Pressure | Medium Pressure |
| Power | Pneumatic |
| Temperature Of Media | Medium Temperature |
| Media | Water |