| Condition | New |
|---|---|
| Data Interface | Wired |
| Certifications | Explosion Proof, Intrinsically Safe, Non-incendive, Dust |
| Safety Certifications | NIL |
| Supply Media | Air |
| Port | Main Ports In China |
|---|---|
| Packaging Details | Packing: Carton Box Weight: 1.5Kg/set Dimension:250MMX100MMX80MM |
| Supply Ability | 100 Set/Sets per Week |
| Place of Origin | Guangdong, China |
| Brand Name | Fisher |
| Port | Main Ports In China |
|---|---|
| Packaging Details | Packing type: cardboard box/non-fumigation wooden box |
| Supply Ability | 100 Set/Sets per Week |
| Place of Origin | China |
| Brand Name | Fisher Gulde |
| Deadband Adjustment | Adjustable Deadband To Accommodate Different Applications |
|---|---|
| Digital Communication Interface | Optional RS485 Modbus RTU Or FOUNDATION Fieldbus Interface |
| Protection Level | IP66 |
| Output Signal | 4-20mA DC, HART Protocol, Etc |
| Local Display | 4-digit LCD Screen, Which Can Display Current Analog Input Value, Output Value, Set Value, And Device Status Information |
| Protection Level | IP66 |
|---|---|
| Deadband Adjustment | Adjustable Deadband To Accommodate Different Applications |
| Diagnostic Function | It Can Automatically Detect Faults And Device Status, And Provide Warning And Fault Prompt Information |
| Local Display | 4-digit LCD Screen, Which Can Display Current Analog Input Value, Output Value, Set Value, And Device Status Information |
| Power Supply | 12-42V DC Power Supply |
| Stroke Length | 0-100mm |
|---|---|
| Supply Pressure | 3-15psi |
| Valve Size | 1/2-2 Inch |
| Accuracy | ±0.2% Of Span |
| Humidity Range | –40 To 85ºC (-40 To 185ºF) |
| Input Signal | 4-20mA DC, 1-5V DC, 0-10V DC, HART Protocol, Etc |
|---|---|
| Protection Level | IP66 |
| Diagnostic Function | It Can Automatically Detect Faults And Device Status, And Provide Warning And Fault Prompt Information |
| Accuracy | Up To 0.075% Under Nominal Conditions |
| Deadband Adjustment | Adjustable Deadband To Accommodate Different Applications |
| Communication Protocol | 4-20 HART |
|---|---|
| Process Temperature Range | Up To 1300 °F (705 °C) Or 1922 °F (1050 °C) |
| Ambient Temperature Range | 40 To +149 °F (-40 To +65 °C) |
| Measurement Type | Oxygen, Zirconia - Brazed Disk |
| Dimensions | Probe Length Options From 18 In To 6 Ft |
| Mounting Type | Integral Mounted |
|---|---|
| Process Control | Flow, Pressure, Temperature, Level |
| Type | Digital Positioner |
| Area Classification | Intrinsically Safe, Non-incendive For CSA And FM |
| Data Interface | Wired |
| Maximum Hysteresis | 0.3 % |
|---|---|
| Stroke Range | 8-260 Mm |
| Model Number | SRD991 |
| Input Pressure | 1.4-6 Bar |
| Linearity | < 0.4 % Of The Travel Span |