| Input Signal | 4-20 MA HART |
|---|---|
| Packaging Details | Corrugated box + Wooden crate + Protection |
| Delivery Time | 60-75 work days |
| Payment Terms | T/T |
| Supply Ability | 1000 units per year |
| Input Signal | 4-20 MA HART |
|---|---|
| Air Supply | 1.4 To 10.3 Bar (20 To 150 Psig) |
| Protection Rating | IP66 |
| Operating Temperature | -40°C To 80°C (-40°F To 176°F) |
| Communication Protocol | HART 6/7 |
| Input Signal | 4-20 MA HART |
|---|---|
| Air Supply | 1.4 To 10.3 Bar (20 To 150 Psig) |
| Protection Rating | IP66 |
| Operating Temperature | -40°C To 80°C (-40°F To 176°F) |
| Communication Protocol | HART 6/7 |
| Input Signal | 4-20 MA HART |
|---|---|
| Packaging Details | Corrugated box + Wooden crate + Protection |
| Delivery Time | 60-75 work days |
| Payment Terms | T/T |
| Supply Ability | 1000 units per year |
| Storage Temperature Limits | -58° F To 185° F (-50° C To 85° C) |
|---|---|
| Supply Pressure Effect | 0.05% Per Psi Unit |
| Customized Support | OEM, ODM, OBM |
| Repeatability | ± 0.3% Full Span |
| Temperature Effect | < 0.005% /° F Typical; -40° F To 180° F (< 0.01% /° C ) |
| Communication Interface | HART, FOUNDATION Fieldbus, Profibus PA |
|---|---|
| Action Time | 0.3-30 Seconds |
| Display Screen | LCD Display Screen, Which Can Display Current Position, Power Status, And Other Information |
| Installation Method | Bracket Or Flange Installation |
| Maximum Output Torque | 600 Nm |
| Storage Temperature Limits | -58° F To 185° F (-50° C To 85° C) |
|---|---|
| Supply Pressure Effect | 0.05% Per Psi Unit |
| Customized Support | OEM, ODM, OBM |
| Repeatability | ± 0.3% Full Span |
| Temperature Effect | < 0.005% /° F Typical; -40° F To 180° F (< 0.01% /° C ) |
| Flow Characteristics | Modified Equal Percentage, Linear |
|---|---|
| Operating Temperature | Low Temperature (-40F), High Temperature (250F) |
| Process Connection Type | Flanged |
| Critical Service | Cavitation, Noise Abatement |
| Shutoff Class | Class IV (FCI 70-2), Class VI (FCI 70-2) |
| Operating Temperature | -52 To 85 °C (-62 To 185 °F) |
|---|---|
| Current Signal Output | 4 - 20 MA |
| Power Supply | Two - Wire, 4 - 20 MA, 10.0 To 30.0 VDC |
| Power Supply Range | 12.5 To 40 VDC (typically 24 VDC) |
| Communication Protocol | HART Protocol |
| Input Signal | 4-20 MA HART |
|---|---|
| Air Supply | 1.4 To 10.3 Bar (20 To 150 Psig) |
| Protection Rating | IP66 |
| Operating Temperature | -40°C To 80°C (-40°F To 176°F) |
| Communication Protocol | HART 6/7 |