| Communication Platform | HART |
|---|---|
| Type | Digital Valve Positioner |
| Supply Pressure | 20 - 100 Psi (1.4 – 7 Bar) |
| Warranty | 1 Year |
| Shell Material | Industrial Aluminum Housing |
| Supply Pressure | 20 - 100 Psi (1.4 – 7 Bar) |
|---|---|
| Warranty | 1 Year |
| Certifications | ATEX, FM, IEC, And CSA Approvals. Intrinsically Safe And Non-incendive (energy Limited) |
| Type | Digital Valve Positioner |
| Communication Platform | HART |
| Model | 500D VeCTor D Trim |
|---|---|
| Trim Design | Multi Stage Pressure Reducing Trim Up To Level 40 |
| Trim Materials | SUS410SS, SUS630, SUS316, INCONEL |
| Flow Characteristics | Linear, Modified Eq% |
| Rangeability | 50:1 ~ 20:1 |
| Operating Temperature | -50°C To +85°C |
|---|---|
| Supply Pressure(Single-Acting) | 20 To 100 Psi Max (1.4 To 6.9 Bar) |
| Supply Pressure(Double-Acting) | 20 To 150 Psi Max (1.4 To 10.3 Bar) |
| Pneumatics Action | Single Or Double Acting, Fail Safe;Rotary And Linear |
| Signal - Communication | HART 5 Or 7 Over 4-20mA |
| Standard Operating Temperature | -20°C To 70°C, Custom Range Available On Request |
|---|---|
| Operating Pressure | 3-7 Bar, Design Pressure Up To 10 Bar |
| Housing Material Option 1 | Painted RAL 7001 Aluminium |
| Housing Material Option 2 | Stainless Steel 316 |
| Pilot Signal Connection | ND 1/4" |
| Body Materials | Carbon Steel |
|---|---|
| Working Range | -10 To +114 % |
| Rated Travel | 7.5/15/30 |
| Model Number | TS800 |
| Opening Angle | 24 To 100° |
| Power Supply | Loop Powered From 4-20mA Control Signal |
|---|---|
| Load Voltage | 11.0 VDC At 20 MA DC / 10.0 VDC At 4 MA DC |
| Acting Type | Single Or Double |
| Supply Medium | Air Or Nitrogen |
| Digital Communicatin | HART 7 |
| Temperature Of Media | High Temperature, Low Temperature, Medium Temperature, Normal Temperature |
|---|---|
| Hysteresis | ≤0.3 % |
| Degree Of Protection | IP 66/NEMA 4X |
| Minimum Current | 3.6 MA For Display 3.8 MA For Operation |
| Static Destruction Limit | 100 MA |
| Diagnostics | Yes |
|---|---|
| Ingress Protection | IP66 / Type 4X |
| Operating Temperature | -55 °C To +85 °C (-67 °F To +185 °F) |
| Communications Protocol | Analog, HART, Foundation Fieldbus, Discrete I/O |
| Packaging Details | Cardboard box + protection |
| Ingress Protection | IP66 |
|---|---|
| Diagnostics | Yes |
| Air Consumption | 0.3 SCFM (standard); 0.075 SCFM (low-bleed) @ 60 Psi |
| Communications Protocol | Analog, HART, Foundation Fieldbus, Discrete I/O |
| Operating Temperature | -55 °C To +85 °C (-67 °F To +185 °F) |