| Analogue Outputs | 4...20 MA |
|---|---|
| Ultra-low And High-temperature Media | -200...+400°C |
| Flow Rate | DN10:0.1-10m/s |
| Connectivity | Flange |
| Maximum Pressure | 200 Barg |
| Medium Temperature Range | -40 To +150 °C (-40 To +302 °F) |
|---|---|
| Accuracy | ±0.15 % |
| Measurement Range | 0 To 180 000 Kg/h (0 To 6615 Lb/min) |
| Medium | Liquid, Gas |
| Liquid, Gas | PN 100, Class 600, 63K |
| Type | Coriolis Meters |
|---|---|
| Material | Stainless Steel |
| Model Number | Proline Promass E 300 |
| Medium Temperature Range | -40 To +150 °C (-40 To +302 °F) |
| Inputs | Status Input 4-20 MA Input |
| Nominal Diameter Range | DN 8 To 250 (⅜ To 10") |
|---|---|
| Measuring Range | 0 To 2 200 000 Kg/h (0 To 80 840 Lb/min) |
| Medium Temperature Range | Standard: –50 To +150 °C (–58 To +302 °F) Option: –50 To +240 °C (–58 To +464 °F) High Temperatur Option: –50 To +350 °C (–58 To +662 °F) Option: –196 To +150 °C (–320 To +302 °F) |
| Mass Flow (liquid) | ±0.10 % (standard), 0.05 % (option) |
| Mass Flow (gas) | ±0.25 % |
| Volume Flow (liquid) | ±0.10 % |
|---|---|
| Measuring Range | 0 To 2 200 000 Kg/h (0 To 80 840 Lb/min) |
| Wetted Materials | Measuring Tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022) Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022); 1.4301 (F304) |
| Nominal Diameter Range | DN 8 To 250 (⅜ To 10") |
| Medium Temperature Range | Standard: –50 To +150 °C (–58 To +302 °F) Option: –50 To +240 °C (–58 To +464 °F) High Temperatur Option: –50 To +350 °C (–58 To +662 °F) Option: –196 To +150 °C (–320 To +302 °F) |
| Mounting | Horizontal/vertical/in-line |
|---|---|
| Sealing Rating | ANSI Class 150/300/600 |
| Connection | Flange/Threaded/Butt-weld |
| Explosion-proof Certification | ATEX Zone 1/IECEx |
| Control Signal | 4-20mA/Modbus/HART |
| Device Serial Number | Unique Hardware Identifier |
|---|---|
| Sensor Model | Matching Coriolis Force Sensor |
| Measuring Range | Flow/density Measurement Upper And Lower Limits |
| Accuracy Level | Such As ±0.05% Of Reading |
| Output Protocol | HART/Modbus/FF, Etc. |
| Conditional | New |
|---|---|
| Output Signal | 4 To 20 MA With HART |
| Heating Jacket | Class 150 |
| Temperature Sensor | Thermistor |
| Protection | IP66/67 (option: IP68) |
| Volume Flow (option) | ±0.2 % O.r. ± 2 Mm/s (0.08 In/s) Flat Spec |
|---|---|
| Type | Digital |
| Accuracy | +/-0.05% |
| Medium | Air |
| Measuring Range | 0.5 M3/h To 263000 M3/h (2.5gal/min To 1665 Mgal/d) |
| Product Name | Proline Promass F 300 Coriolis Flowmeter |
|---|---|
| Nominal Diameter Range | DN 8 To 250 |
| Measuring Range | 0 To 2 200 000 Kg/h (0 To 80 840 Lb/min) |
| Max. Process Pressure | PN 100, Class 600, 63K |
| Sensor Housing Material | Standard: 1.4301 (304) /Option: 1.4404 (316/316L) |