| Process Connections | Threaded, Flange, Hygienic, Remote Seal |
|---|---|
| Wireless Range | Internal Antenna (225 M) |
| Rangedown | Up To 150:1 |
| Condition | New |
| Fluid Media | Air, Water, Oil, Gas |
| Customized Support | OEM, ODM, OBM |
|---|---|
| Ingress Protection | Ip65, Ip67, Ip68, Ip66 |
| Service Life Of The Power Module | Up To 10 Years, Replaceable On Site |
| Measuring Range Differential Pressure | 137,89bar (2000psi) |
| Warranty | 1 Year |
| Temperature Range | 0 - 200 °C |
|---|---|
| Fluid Media | Air, Water, Oil, Gas |
| Process Connections | Threaded, Flange, Hygienic, Remote Seal |
| Condition | New |
| Supply Voltage | 12 To 42.4 VDC |
| Storage Function | 1000 Record Can Be Saved |
|---|---|
| Wetted Material | Stainless Steel; 316 / 316L And CF3M |
| Rangedown | Up To 150:1 |
| Port | Main Ports In China |
| Wireless Update Rate | Wireless Update Rate |
| Ambient Relative Humidity | ≤85% |
|---|---|
| Connection Type | Flange, Thread |
| Diagnostics | Basic Diagnostics, Process Alerts, Loop Integrity Diagnostics, Plugged Impulse Line Diagnostics |
| Pressure | 2.5-6.4Mpa |
| Wireless Update Rate | Wireless Update Rate |
| Process Connections | Threaded, Flange, Hygienic, Remote Seal |
|---|---|
| Wireless Range | Internal Antenna (225 M) |
| Rangedown | Up To 150:1 |
| Condition | New |
| Fluid Media | Air, Water, Oil, Gas |
| Ambient Relative Humidity | ≤85% |
|---|---|
| Connection Type | Flange, Thread |
| Diagnostics | Basic Diagnostics, Process Alerts, Loop Integrity Diagnostics, Plugged Impulse Line Diagnostics |
| Pressure | 2.5-6.4Mpa |
| Wireless Update Rate | Wireless Update Rate |
| Port | Main Ports In China |
|---|---|
| Connection Type | Flange, Thread |
| Pressure Rating | Class 125 To Class 300 |
| Flange Options | ANSI Class 150 To 1500 |
| Wetted Material | Stainless Steel; 316 / 316L And CF3M |
| Ambient Relative Humidity | ≤85% |
|---|---|
| Connection Type | Flange, Thread |
| Diagnostics | Basic Diagnostics, Process Alerts, Loop Integrity Diagnostics, Plugged Impulse Line Diagnostics |
| Pressure | 2.5-6.4Mpa |
| Wireless Update Rate | Wireless Update Rate |
| Alarm Outputs | No Flow, High Alarm And Low Alarm |
|---|---|
| Fluid Media | Air, Water, Oil, Gas |
| Diagnostics | Basic Diagnostics, Process Alerts, Loop Integrity Diagnostics, Plugged Impulse Line Diagnostics |
| Communication Protocol | 4-20 MA HART®, WirelessHART®, FOUNDATION™ Fieldbus, PROFIBUS® PA, 1-5 V Low Power HART® |
| Wireless Update Rate | 1 Sec. To 60 Min., User Selectable |