| Valve Type | Linear Or Rotary Motion Control Valve |
|---|---|
| Repeatability | ± 0.3 Percent Full Span |
| Required Terminal Voltage | 9 VDC At 20mA |
| Power Supply | 4-20mA |
| Minimum Current Signal | 3.2mA |
| Mounting Compatibility | GULDE Full Series And Other Actuators Meeting IEC/VDI/NAMUR Standards |
|---|---|
| Input Signal | 4-20 MA DC Standard, Min. 8.5V (analog) / 9.0V (HART) |
| Output Action | 0.5 To 7 Bar, Single-acting, Reaches 95% Of Supply |
| Air Supply | Max 7 Bar, Requires Clean Dry Air Per ISA 7.0.01 Standard |
| Operating Temperature | -40 To 85 °C, LCD May Fail Below -20 °C |
| Input Signal | 4 To 20 MA DC Constant Current With 30 VDC |
|---|---|
| Supply Pressure | 0.3 Bar (5 Psi) Above Actuator Requirement |
| Supply Medium | Air Or Natural Gas |
| Independent Linearity | ±2 Percent Of Output Signal Span |
| Hysteresis | 0.6 Percent Of Span |
| Conformity/Linearity | ± 0.5% Full Span |
|---|---|
| Supply Pressure Effect | 0.05% Per Psi Unit |
| Name | Masoneilan SVI FF |
| Operating | -40° F To 185° F (-40° C To 85° C) |
| Accuracy | ± 0.5% |
| Humidity Range | 0% To 95% (non-condensing) |
|---|---|
| Communication Interface | HART, FoxCom, RS-232, RS-485 |
| Output Stability | ±0.01% Of Output Reading Per Hour |
| Optional Accessories | Pressure Modules, Temperature Sensors, Communication Cables, PC Software |
| Battery Life | Approx. 20 Hours Continuous Use At 20 MA Output |
| Output Resolution | 0.001 MA |
|---|---|
| Temperature Range | -10°C To 55°C |
| Dimensions | 144 Mm X 80 Mm X 44 Mm |
| Display | LCD Display, 2 Lines X 16 Characters |
| Humidity Range | 0% To 95% (non-condensing) |
| Communication Interface | HART, FOUNDATION Fieldbus, Profibus PA |
|---|---|
| Action Time | 0.3-30 Seconds |
| Display Screen | LCD Display Screen, Which Can Display Current Position, Power Status, And Other Information |
| Installation Method | Bracket Or Flange Installation |
| Maximum Output Torque | 600 Nm |
| Condition | New |
|---|---|
| Maximum Hysteresis | 0.3 % |
| Model Number | SRD991 |
| Pneumatic Operation | Single Acting Double Acting |
| Stroke Range | 8-260 Mm |
| Model Number | SVI1000/SVI2/SVI3 |
|---|---|
| Hazardous Area Certification | ATEX / FM / CSA / IEC Intrinsic |
| Valve Setpoint | 4-20mA, 450 Ohms Input Resistance |
| Case/Cover | Aluminum ASTM 360 |
| Remote Position Sensor | 1 KOhms |
| Shell Material | Industrial Aluminum Housing |
|---|---|
| Minimum Current Signal | 3.2mA |
| Case/Cover | Aluminum ASTM 360 |
| Required Terminal Voltage | 9Vdc At 20mA |
| Valve Setpoint | 4-20mA, 450 Ohms Input Resistance |