| Input Signal Options | 4-20 MA (analog), HART, FOUNDATION Fieldbus |
|---|---|
| Air Supply Pressure | 3-7 Bar |
| Protection Rating | IP66 |
| Accuracy | ≤ 0.25 % |
| Temperature Range | -52 °C To +85 °C (-62 °F To +185 °F) |
| Supply Pressure Effect | 0.05% Per Psi Unit |
|---|---|
| Ambient Humidity | 10 To 95% Non-condensing |
| Storage Temperature Limits | -58° F To 185° F (-50° C To 85° C) |
| Temperature Effect | < 0.005% /° F Typical; -40° F To 180° F (< 0.01% /° C ) |
| Name | Masoneilan SVI FF |
| Features | Easy, Simple, Accurate |
|---|---|
| Repeatability | +/- 0.3 Percent Full Span |
| Pneumatics | Air Or Sweet Natural Gas – Regulated And Filtered |
| Signal Communication | HART 5 Or 7 Over 4-20mA |
| Linearity | +/- 1 Percent Full Scale |
| Linearity | +/- 1 Percent Full Scale |
|---|---|
| Materials | Copper-free Aluminum Housing |
| Accuracy | +/- 0.5 Percent Full Span |
| Operating Temperature | -50°C To +85°C |
| Diagnostics | Standard Diagnostics,Advanced Diagnostics |
| Maximum Hysteresis | 0.3 % |
|---|---|
| Stroke Range | 8-260 Mm |
| Model Number | SRD991 |
| Input Pressure | 1.4-6 Bar |
| Linearity | < 0.4 % Of The Travel Span |
| Condition | New |
|---|---|
| Diagnostics | Standard Diagnostics,Advanced Diagnostics |
| Operating Temperature | -50°C To +85°C |
| Pneumatics | Air Or Sweet Natural Gas – Regulated And Filtered |
| Pneumatics Action | Single Or Double Acting, Fail Safe,Rotary And Linear |
| Pneumatics | Air Or Sweet Natural Gas – Regulated And Filtered |
|---|---|
| Air Supply Pressure | Single-Acting(1.4 To 6.9 Bar), Double-Acting(1.4 To 10.3 Bar) |
| Air Delivery | 280 SLPM @ 30psi |
| Materials | Copper-free Aluminum Housing |
| Power Supply | 4-20 MA |
| Input Signal | Electric |
|---|---|
| Humidity | 0-100% Non-condensing |
| Application Industry | MiningApplication Industry, Pulp & Paper, Steel & Primary Metals, Food & Beverage, Corn Wet Milling & Ethanol, Upstream Exploration & Production, Wastewater, Agriculture & Irrigation, Flood Control System, Pharmaceutical, Petrochemicals, Biofuels, Other In |
| Voltage Supply (maximum) | 30 VDC |
| Position Control | Throttling Control, On/Off |
| Output Signal | 0 To 10 V, RB = 1 KΩ |
|---|---|
| Warranty | 1 Year |
| Input Signal | 0 To 10 V, Ri = 20 KΩ · 0 To 20 MA, Ri = 50 Ω |
| Ambient | 0 To 50 °C |
| Storage | –20 To +70 °C |
| Max Pressure | 100PSI |
|---|---|
| External Parts | Stainless Steel 1.4571 And 1.4301 |
| Ex | Ex Ia IIC T4 |
| Weight | 2kg |
| Model Number | 3800sa |