| Warranty | 1 YEAR |
|---|---|
| Customized Support | OEM |
| Model Number | 3200MD |
| Temperature Of Media | Low Temperature |
| Application | General |
| Accuracy | ± 0.5% |
|---|---|
| Name | Masoneilan SVI FF |
| Repeatability | ± 0.3% Full Span |
| Conformity/Linearity | ± 0.5% Full Span |
| Supply Pressure Effect | 0.05% Per Psi Unit |
| Diagnostic Functions | Provides Status Reports And Fault Information, Supports Equipment Management And Maintenance |
|---|---|
| Linearity | Less Than 0.5% Of The Maximum Travel Value |
| Zero Point Drift | Less Than 0.1% Of The Maximum Travel Value |
| Material | Aluminum Alloy Or Stainless Steel |
| Suitable Media | Non-corrosive Media Such As Liquids, Gases, And Steam |
| Mounting Compatibility | GULDE Full Series And Other Actuators Meeting IEC/VDI/NAMUR Standards |
|---|---|
| Input Signal | 4-20 MA DC Standard, Min. 8.5V (analog) / 9.0V (HART) |
| Output Action | 0.5 To 7 Bar, Single-acting, Reaches 95% Of Supply |
| Air Supply | Max 7 Bar, Requires Clean Dry Air Per ISA 7.0.01 Standard |
| Operating Temperature | -40 To 85 °C, LCD May Fail Below -20 °C |
| Shell Material | Industrial Aluminum Housing |
|---|---|
| Data Interface | Wired |
| Model Number | 3582i |
| Process Control | Flow, Pressure, Temperature, Level |
| Supply Media | Air |
| Application | General |
|---|---|
| Material | Stainless Steel |
| Temperature Of Media | High Temperature |
| Pressure | Medium Pressure |
| Power | Pneumatic |
| Humidity Range | 0% To 95% (non-condensing) |
|---|---|
| Communication Interface | HART, FoxCom, RS-232, RS-485 |
| Output Stability | ±0.01% Of Output Reading Per Hour |
| Optional Accessories | Pressure Modules, Temperature Sensors, Communication Cables, PC Software |
| Battery Life | Approx. 20 Hours Continuous Use At 20 MA Output |
| Output Resolution | 0.001 MA |
|---|---|
| Temperature Range | -10°C To 55°C |
| Dimensions | 144 Mm X 80 Mm X 44 Mm |
| Display | LCD Display, 2 Lines X 16 Characters |
| Humidity Range | 0% To 95% (non-condensing) |
| Accessories | Overload Protection, Manual Operation, Protective Cover, And Transition Plate |
|---|---|
| Positioning Accuracy | Typically ±0.5% |
| Operating Temperature Range | -40°C To +85°C |
| Mounting | Vertical Or Suspended Mounting Options |
| Power Supply Voltage | 24VDC Or 110-240VAC |
| Repeatability | +/- 0.3 Percent Full Span |
|---|---|
| Condition | New |
| Linearity | +/- 1 Percent Full Scale |
| Signal Communication | HART 5 Or 7 Over 4-20mA |
| Supply Pressure | 20 To 150psi |