| Signal Range | 4-20mA |
|---|---|
| Supply Air Pressure | 1.4-10 Bar (20-145 Psig) |
| Ambient Temperature | -40 ... 85°C (-40 ... 185°F) |
| Protection Class | IP 66/Type 4X |
| Housing And Cover | Aluminum (Alloy No. 230) Powder Coated |
| Protection Level | IP66 |
|---|---|
| Deadband Adjustment | Adjustable Deadband To Accommodate Different Applications |
| Diagnostic Function | It Can Automatically Detect Faults And Device Status, And Provide Warning And Fault Prompt Information |
| Local Display | 4-digit LCD Screen, Which Can Display Current Analog Input Value, Output Value, Set Value, And Device Status Information |
| Power Supply | 12-42V DC Power Supply |
| Signal Range | 4 To 20 MA |
|---|---|
| Media | Gas |
| Minimum Current | 3.6 MA For Display 3.8 MA For Operation |
| Temperature Of Media | High Temperature, Low Temperature, Medium Temperature, Normal Temperature |
| Degree Of Protection | IP 66/NEMA 4X |
| Input Signal | 4-20mA DC, 1-5V DC, 0-10V DC, HART Protocol, Etc |
|---|---|
| Protection Level | IP66 |
| Diagnostic Function | It Can Automatically Detect Faults And Device Status, And Provide Warning And Fault Prompt Information |
| Accuracy | Up To 0.075% Under Nominal Conditions |
| Deadband Adjustment | Adjustable Deadband To Accommodate Different Applications |
| Deviation | ≤1 % |
|---|---|
| Application | Industry |
| Direction Of Action | Reversible |
| Temperature | ≤0.15 %/10 K |
| Sensitivity | ≤0.1 % |
| Customized Support | OEM |
|---|---|
| Deviation | ≤1 % |
| Power | Pneumatic |
| Hysteresis | ≤0.3 % |
| Temperature Of Media | High Temperature, Low Temperature, Medium Temperature, Normal Temperature |
| Temperature | ≤0.15 %/10 K |
|---|---|
| Hysteresis | ≤0.3 % |
| Minimum Current | 3.6 MA For Display 3.8 MA For Operation |
| Application | Industry |
| Temperature Of Media | High Temperature, Low Temperature, Medium Temperature, Normal Temperature |
| Input Pressure | 1.4...6 Bar |
|---|---|
| Maximum Hysteresis | 0.3 % |
| Ambient Air Temperature For Operation | -40...80 °C (-40...176 °F) |
| Communication Port Protocol | HART, 4...20 MA Profibus FOUNDATION Fieldbus |
| IP Degree Of Protection | IP66 |
| Minimum Current | 3.6 MA For Display 3.8 MA For Operation |
|---|---|
| Signal Range | 4 To 20 MA |
| Temperature Of Media | High Temperature, Low Temperature, Medium Temperature, Normal Temperature |
| Degree Of Protection | IP 66/NEMA 4X |
| Direction Of Action | Reversible |
| Rangedown | Up To 10:1 (5:1 For Range 1) |
|---|---|
| Output Signal | Pneumatic Pressure Up To 145 Psig (10 Bar) |
| Ambient Temp | -10 To +60°C, -10 To +60°C, -10 To +60°C |
| Power Supply | 24V DC (9.5V Minimum For Analog Control, 10V For HART) |
| Precision | High |