| Warranty | 1 Year |
|---|---|
| Ambient Temperature | -40 To 85°C (-40 To 185°F) |
| Required Compliance Voltage | 9 Vdc At 20 MA 11 Vdc At 4 MA |
| Humidity Limits | 100% RH Non-condensing |
| Min/Max Current | 3.2 MA/24 MA |
| Condition | New |
|---|---|
| Hysteresis + DeadBand | +/- 0.3 Percent Full Span |
| Minimum Current Signal | 3.2 MA |
| Pneumatics | Air Or Sweet Natural Gas – Regulated And Filtered |
| Signal Communication | HART 5 Or 7 Over 4-20mA |
| Operating Temperature Limits | -58°F To 185°F (-50°C To 85°C) |
|---|---|
| Supply Pressure Effect | 0.05% Per Psi |
| Insulation Resistance | Greater Than 10 G Ohms At 50% RH |
| Relative Humidity | 10 To 90% Non-condensing |
| Packaging Details | Cardboard boxes/Wooden crates |
| Communication | HART Revision 5 Or 7 Protocol |
|---|---|
| Air Supply Pressure | Single-Acting: 20 To 100 Psi Max (1.4 To 6.9 Bar) |
| Actuator Size | 2-12 Inch |
| Materials | Tropicalized Aluminum |
| Air Supply | 30 Psi (2.1 Bar |
| Model Number | SVI2 |
|---|---|
| Storage Temperature Limits | -58°F To 200°F (-50°C To 93°C) |
| Relative Humidity | 10 To 90% Non-condensing |
| Fast Transient Burst | No Effect At 2 KV |
| Customized Support | OEM, ODM, OBM |
| Temperature | ≤0.15 %/10 K |
|---|---|
| Hysteresis | ≤0.3 % |
| Minimum Current | 3.6 MA For Display 3.8 MA For Operation |
| Application | Industry |
| Temperature Of Media | High Temperature, Low Temperature, Medium Temperature, Normal Temperature |
| Operating Temperature Limits | -58°F To 185°F (-50°C To 85°C) |
|---|---|
| Supply Pressure Effect | 0.05% Per Psi |
| Insulation Resistance | Greater Than 10 G Ohms At 50% RH |
| Fast Transient Burst | No Effect At 2 KV |
| Relative Humidity | 10 To 90% Non-condensing |
| Operating Temperature Limits | -58°F To 185°F (-50°C To 85°C) |
|---|---|
| Supply Pressure Effect | 0.05% Per Psi |
| Insulation Resistance | Greater Than 10 G Ohms At 50% RH |
| Fast Transient Burst | No Effect At 2 KV |
| Relative Humidity | 10 To 90% Non-condensing |
| Input Signal | 4 To 20 MA DC Constant Current With 30 VDC |
|---|---|
| Supply Pressure | 0.3 Bar (5 Psi) Above Actuator Requirement |
| Supply Medium | Air Or Natural Gas |
| Independent Linearity | ±2 Percent Of Output Signal Span |
| Hysteresis | 0.6 Percent Of Span |
| Input Signal | 4 To 20 MA DC Constant Current With 30 VDC |
|---|---|
| Supply Pressure | 0.3 Bar (5 Psi) Above Actuator Requirement |
| Supply Medium | Air Or Natural Gas |
| Independent Linearity | ±2 Percent Of Output Signal Span |
| Hysteresis | 0.6 Percent Of Span |