| Warranty | 1 Year |
|---|---|
| Ambient Temperature | -40 To 85°C (-40 To 185°F) |
| Required Compliance Voltage | 9 Vdc At 20 MA 11 Vdc At 4 MA |
| Humidity Limits | 100% RH Non-condensing |
| Min/Max Current | 3.2 MA/24 MA |
| Diagnostics | Yes |
|---|---|
| Supply Media | Air, Natural Gas, Nitrogen |
| Warranty | 1 Year |
| Signal Range | 4 To 20 MA |
| Data Interface | Wired |
| Storage Temperature Limits | -58° F To 185° F (-50° C To 85° C) |
|---|---|
| Supply Pressure Effect | 0.05% Per Psi Unit |
| Customized Support | OEM, ODM, OBM |
| Repeatability | ± 0.3% Full Span |
| Temperature Effect | < 0.005% /° F Typical; -40° F To 180° F (< 0.01% /° C ) |
| Communication Protocol | 4-20mA Analog |
|---|---|
| Model Number | 3582i |
| Mounting Type | Actuator Mounted |
| Data Interface | Wired |
| Safety Certifications | NIL |
| Area Classification | Explosion Proof, Intrinsically Safe, Non-incendive, Dust |
|---|---|
| Supply Media | Air |
| Shell Material | Industrial Aluminum Housing |
| Model Number | 3582i |
| Input Signal | Electric |
| Accuracy | ± 0.5% |
|---|---|
| Name | Masoneilan SVI FF |
| Repeatability | ± 0.3% Full Span |
| Conformity/Linearity | ± 0.5% Full Span |
| Supply Pressure Effect | 0.05% Per Psi Unit |
| Safety Features | Overvoltage Protection, Reverse Polarity Protection, Short-circuit Protection |
|---|---|
| Ramp Function | User-defined Ramp Function With Adjustable Time |
| Optional Accessories | Pressure Modules, Temperature Sensors, Communication Cables, PC Software |
| Step Function | 25% Step, 100% Step, User-defined Step |
| Certifications | CE, CSA, FM, ATEX, IECEx, GOST-R |
| Output Resolution | 0.001 MA |
|---|---|
| Temperature Range | -10°C To 55°C |
| Dimensions | 144 Mm X 80 Mm X 44 Mm |
| Display | LCD Display, 2 Lines X 16 Characters |
| Humidity Range | 0% To 95% (non-condensing) |
| Safety Features | Overvoltage Protection, Reverse Polarity Protection, Short-circuit Protection |
|---|---|
| Temperature Range | -10°C To 55°C |
| Output Resolution | 0.001 MA |
| Ramp Function | User-defined Ramp Function With Adjustable Time |
| Accuracy | 0.01% Full Scale |
| Input Signal | 4-20mA DC, 1-5V DC, 0-10V DC, HART Protocol, Etc |
|---|---|
| Protection Level | IP66 |
| Diagnostic Function | It Can Automatically Detect Faults And Device Status, And Provide Warning And Fault Prompt Information |
| Accuracy | Up To 0.075% Under Nominal Conditions |
| Deadband Adjustment | Adjustable Deadband To Accommodate Different Applications |