| Conformity/Linearity | ± 0.5% Full Span |
|---|---|
| Supply Pressure Effect | 0.05% Per Psi Unit |
| Name | Masoneilan SVI FF |
| Operating | -40° F To 185° F (-40° C To 85° C) |
| Accuracy | ± 0.5% |
| Accuracy | 0.025% Full Scale |
|---|---|
| Output Stability | ±0.01% Of Output Reading Per Hour |
| Communication Interface | HART, FoxCom, RS-232, RS-485 |
| Display | LCD Display, 2 Lines X 16 Characters |
| Weight | Approx. 300g |
| Humidity Range | 0% To 95% (non-condensing) |
|---|---|
| Communication Interface | HART, FoxCom, RS-232, RS-485 |
| Output Stability | ±0.01% Of Output Reading Per Hour |
| Optional Accessories | Pressure Modules, Temperature Sensors, Communication Cables, PC Software |
| Battery Life | Approx. 20 Hours Continuous Use At 20 MA Output |
| Safety Features | Overvoltage Protection, Reverse Polarity Protection, Short-circuit Protection |
|---|---|
| Temperature Range | -10°C To 55°C |
| Output Resolution | 0.001 MA |
| Ramp Function | User-defined Ramp Function With Adjustable Time |
| Accuracy | 0.01% Full Scale |
| Deadband Adjustment | Adjustable Deadband To Accommodate Different Applications |
|---|---|
| Digital Communication Interface | Optional RS485 Modbus RTU Or FOUNDATION Fieldbus Interface |
| Protection Level | IP66 |
| Output Signal | 4-20mA DC, HART Protocol, Etc |
| Local Display | 4-digit LCD Screen, Which Can Display Current Analog Input Value, Output Value, Set Value, And Device Status Information |
| Operating Temperature Range | -40℃ To 70℃ |
|---|---|
| Digital Communication Interface | Optional RS485 Modbus RTU Or FOUNDATION Fieldbus Interface |
| Protection Level | IP66 |
| Deadband Adjustment | Adjustable Deadband To Accommodate Different Applications |
| Diagnostic Function | It Can Automatically Detect Faults And Device Status, And Provide Warning And Fault Prompt Information |
| Accessories | Overload Protection, Manual Operation, Protective Cover, And Transition Plate |
|---|---|
| Positioning Accuracy | Typically ±0.5% |
| Operating Temperature Range | -40°C To +85°C |
| Mounting | Vertical Or Suspended Mounting Options |
| Power Supply Voltage | 24VDC Or 110-240VAC |
| Display Screen | LCD Display Screen, Which Can Display Current Position, Power Status, And Other Information |
|---|---|
| Ambient Temperature | -20℃ ~ +70℃ |
| Maximum Output Torque | 600 Nm |
| Installation Method | Bracket Or Flange Installation |
| Power Supply | 4V DC, 120V AC, Or 240V AC |
| Communication Interface | HART, FOUNDATION Fieldbus, Profibus PA |
|---|---|
| Action Time | 0.3-30 Seconds |
| Display Screen | LCD Display Screen, Which Can Display Current Position, Power Status, And Other Information |
| Installation Method | Bracket Or Flange Installation |
| Maximum Output Torque | 600 Nm |
| Data Interface | Wired |
|---|---|
| Diagnosticsue | Yes |
| Input Signal | Electric |
| Process Control | Flow, Pressure, Temperature, Level |
| Mounting Type | Integral Mounted |