Features
Specifications
Input: 4-20 MA DC (resistance 300 Ω)
Communication: HART6 (AVP102)
Air Supply: 140-700 KPa
Air Use: 4 L/min (N) Single-acting At Balance
Max Flow: 110 L/min (N) Single-acting At 400 KPa
Temp Range: -40 To +80°C
Humidity: 10-90% RH
Highlight:

ASCO solenoid spool valves with warranty

,

Azbil AVP100 smart valve positioner

,

pneumatic control valves for industrial use

Basic Infomation
Place of Origin: China
Brand Name: Azbil
Model Number: AVP100/AVP102
Payment & Shipping Terms
Packaging Details: Carton + Wooden crate + Protective packaging
Delivery Time: 65 days
Payment Terms: T/T
Supply Ability: 600 units per year
Product Description
Product Overview

Azbil's Smart Valve Positioner 100 Series (AVP100/102) is a microcontroller-based device that converts 4-20 mA DC input signals into pneumatic output to control valve position. The AVP100 is analog-only, while the AVP102 integrates HART6 protocol for bi-directional communication. It supports electrical adjustments for input-valve position relationships, including split-range and custom flow curves. Designed for single/double-acting actuators, it features auto-setup for actuator detection and calibration. The positioner includes a VTD sensor for feedback, EPM for electro-pneumatic conversion, and pilot relay for air amplification, ensuring precise control with diagnostics for reliability in industrial settings.

Key Features
  • Auto-Setup and Calibration: Switch-activated program detects actuator type and adjusts zero/span; manual zero/span via screwdriver.
  • HART Integration (AVP102): Supports HART communicator or CFS100 software for configuration, dummy signals, and diagnostics like deviation alarm and temperature alarm.
  • Control Configuration: PARAM settings for actuator size, hysteresis (LIGHT/MEDIUM/HEAVY), PID parameters for optimized response.
  • Fail-Safe and Safety: Fail-safe position on critical failure, surge absorber, lightning protection (12 kV/1000 A), protective grounding <100 Ω.
  • Maintenance Features: A/M switch for manual air bypass (single-acting), EPM balance adjustment, self-diagnostics for RAM/ROM/NVM errors.
  • Block Diagram: Input conversion, PID calculation, EPM driver, pilot relay, VTD feedback; air supply 140-700 kPa for balanced operation.
  • Reversing Relay for Double-Acting: Integrates for opposite pressure output, with OUT1 through SVP and OUT2 balance.
Technical Specifications
Parameter Details
Input Signal 4-20 mA DC (input resistance 300 Ω)
Communication HART6 (AVP102); CFS100 software compatible
Output Pressure Balanced to supply (140-700 kPa) for double-acting
Air Consumption 4 L/min (N) at balanced state for single-acting
Max Air Flow 110 L/min (N) at 400 kPa supply for single-acting
Vibration Resistance 20 m/s², 5-400 Hz
Ambient Temperature -40 to +80°C (general); -20 to +55°C (flameproof)
Ambient Humidity 10-90% RH (non-condensing)
Weight 1.7 kg (main unit)
Accuracy ±1.0% F.S. (standard feedback angle ±4° to ±20°)
Lightning Protection Voltage surge 12 kV, current surge 1000 A
Enclosure Watertight IP66/NEMA 4X, cast aluminum with baked acrylic finish
Certifications TIIS Ex d IIC T6; ATEX/IECEx/CCC/CNS flameproof; FM intrinsically safe; CE EMC/RoHS
Electrical Connections G1/2 or M20x1.5
Air Connections Rc1/4 internal thread
Magnetic Field <400 A/m
Applications

Optimized for precision valve positioning in process industries requiring robust performance, such as petrochemical refineries and power plants. Compatible with Azbil HA/PSA/VA actuators, Masoneilan, Fisher, and others for linear or rotary motion. Suitable for hazardous locations with flameproof approvals, supporting control loops in systems with high magnetic interference or vibration.

Frequently Asked Questions
  • What to do if VTD FAULT error? Check feedback lever within ±20° angle, VTD connector, input line; contact Azbil if persists.
  • HI/LO EPM OUT error? Verify air supply, input >4 mA, A/M in Auto, clean nozzle/orifice, adjust EPM balance, test with varying input.
  • OVER TEMP error? Check SVP temperature and relocate to cooler area.
  • LO IIN error? Ensure input signal at least 3.85 mA.
  • ACT ERR error? Increase air supply, verify 1-10 psig, signatore using ValVue, perform value signal.
Contact Us

Phone/WeChat/WhatsApp:

+8613916209596

Email: svetama@gbsxj.com

Related Products
  • Booster Relay: For enhanced air flow in large actuators.
  • CFS100 Field Communication Software: For detailed configuration and diagnostics.
  • HART Communicator Model 375: For AVP102 operations.
  • Extension Lever: For feedback angles exceeding 20°.
  • Conduit Adapters: For electrical connections in hazardous areas.
Ratings & Review

Overall Rating

5.0
Based on 50 reviews for this supplier

Rating Snapshot

The following is the distribution of all ratings
5 stars
100%
4 stars
0%
3 stars
0%
2 stars
0%
1 stars
0%

All Reviews

M
Madiyar serikov
Kazakhstan Feb 3.2026
Great experience with this supplier! Very professional, quick to respond, and clear in communication. The prices were fair, and delivery was even faster than expected. Highly recommend!
M
Muhammad Amir
Pakistan May 9.2025
The product quality is very good
A
Azharu deen
Saudi Arabia May 17.2024
Great buying experience. The seller was very professional, offered a fair price, and delivered exactly on time. Communication was quick and helpful throughout the process. Highly recommended!
Recommended Products
Get in touch with us
Contact Person : Mr. Edward Zhao
Tel : +8615000725058
Characters Remaining(20/3000)