logo

ASCO Solenoid Spool Valves and Azbil 100 Series Model AVP100 102 Smart Valve Positioner Valve Controller

1
MOQ
900 dollars
Price
ASCO Solenoid Spool Valves and Azbil 100 Series Model AVP100 102 Smart Valve Positioner Valve Controller
Features Gallery Product Description Ratings & Review Request A Quote
Features
Specifications
Input: 4-20 MA DC (resistance 300 Ω)
Communication: HART6 (AVP102)
Air Supply: 140-700 KPa
Air Use: 4 L/min (N) Single-acting At Balance
Max Flow: 110 L/min (N) Single-acting At 400 KPa
Temp Range: -40 To +80°C
Humidity: 10-90% RH
Basic Infomation
Place of Origin: China
Brand Name: Azbil
Model Number: AVP100/AVP102
Payment & Shipping Terms
Packaging Details: Carton + Wooden crate + Protective packaging
Delivery Time: 65 days
Payment Terms: T/T
Supply Ability: 600 units per year
Product Description
Product Overview

Azbil's Smart Valve Positioner 100 Series (AVP100/102) is a microcontroller-based device that converts 4-20 mA DC input signals into pneumatic output to control valve position. The AVP100 is analog-only, while the AVP102 integrates HART6 protocol for bi-directional communication. It supports electrical adjustments for input-valve position relationships, including split-range and custom flow curves. Designed for single/double-acting actuators, it features auto-setup for actuator detection and calibration. The positioner includes a VTD sensor for feedback, EPM for electro-pneumatic conversion, and pilot relay for air amplification, ensuring precise control with diagnostics for reliability in industrial settings.

Key Features
  • Auto-Setup and Calibration: Switch-activated program detects actuator type and adjusts zero/span; manual zero/span via screwdriver.
  • HART Integration (AVP102): Supports HART communicator or CFS100 software for configuration, dummy signals, and diagnostics like deviation alarm and temperature alarm.
  • Control Configuration: PARAM settings for actuator size, hysteresis (LIGHT/MEDIUM/HEAVY), PID parameters for optimized response.
  • Fail-Safe and Safety: Fail-safe position on critical failure, surge absorber, lightning protection (12 kV/1000 A), protective grounding <100 Ω.
  • Maintenance Features: A/M switch for manual air bypass (single-acting), EPM balance adjustment, self-diagnostics for RAM/ROM/NVM errors.
  • Block Diagram: Input conversion, PID calculation, EPM driver, pilot relay, VTD feedback; air supply 140-700 kPa for balanced operation.
  • Reversing Relay for Double-Acting: Integrates for opposite pressure output, with OUT1 through SVP and OUT2 balance.
Technical Specifications
Parameter Details
Input Signal 4-20 mA DC (input resistance 300 Ω)
Communication HART6 (AVP102); CFS100 software compatible
Output Pressure Balanced to supply (140-700 kPa) for double-acting
Air Consumption 4 L/min (N) at balanced state for single-acting
Max Air Flow 110 L/min (N) at 400 kPa supply for single-acting
Vibration Resistance 20 m/s², 5-400 Hz
Ambient Temperature -40 to +80°C (general); -20 to +55°C (flameproof)
Ambient Humidity 10-90% RH (non-condensing)
Weight 1.7 kg (main unit)
Accuracy ±1.0% F.S. (standard feedback angle ±4° to ±20°)
Lightning Protection Voltage surge 12 kV, current surge 1000 A
Enclosure Watertight IP66/NEMA 4X, cast aluminum with baked acrylic finish
Certifications TIIS Ex d IIC T6; ATEX/IECEx/CCC/CNS flameproof; FM intrinsically safe; CE EMC/RoHS
Electrical Connections G1/2 or M20x1.5
Air Connections Rc1/4 internal thread
Magnetic Field <400 A/m
Applications

Optimized for precision valve positioning in process industries requiring robust performance, such as petrochemical refineries and power plants. Compatible with Azbil HA/PSA/VA actuators, Masoneilan, Fisher, and others for linear or rotary motion. Suitable for hazardous locations with flameproof approvals, supporting control loops in systems with high magnetic interference or vibration.

Frequently Asked Questions
  • What to do if VTD FAULT error? Check feedback lever within ±20° angle, VTD connector, input line; contact Azbil if persists.
  • HI/LO EPM OUT error? Verify air supply, input >4 mA, A/M in Auto, clean nozzle/orifice, adjust EPM balance, test with varying input.
  • OVER TEMP error? Check SVP temperature and relocate to cooler area.
  • LO IIN error? Ensure input signal at least 3.85 mA.
  • ACT ERR error? Increase air supply, verify 1-10 psig, signatore using ValVue, perform value signal.
Contact Us

Phone/WeChat/WhatsApp:

+8613916209596

Email: svetama@gbsxj.com

Related Products
  • Booster Relay: For enhanced air flow in large actuators.
  • CFS100 Field Communication Software: For detailed configuration and diagnostics.
  • HART Communicator Model 375: For AVP102 operations.
  • Extension Lever: For feedback angles exceeding 20°.
  • Conduit Adapters: For electrical connections in hazardous areas.
Ratings & Review

Overall Rating

5.0
Based on 50 reviews for this supplier

Rating Snapshot

The following is the distribution of all ratings
5 stars
0%
4 stars
0%
3 stars
0%
2 stars
0%
1 stars
0%

All Reviews

F
FLOWSERVE MARK ONE Linear Globe Angle Control Valve Spring Cylinder Valve Pneumatic Actuator
Switzerland Dec 1.2025
great price and fast delivery
Recommended Products
Get in touch with us
Contact Person : Mr. Edward Zhao
Tel : +8615000725058
Characters Remaining(20/3000)