logo

Samson 3730-3 Smart Electropneumatic Positioner HART 4-20mA for Pneumatic Actuators

1
MOQ
US $2,500 ~ $6,000
Price
Samson 3730-3 Smart Electropneumatic Positioner HART 4-20mA for Pneumatic Actuators
Features Gallery Product Description Ratings & Review Request A Quote
Features
Specifications
Material: Stainless Steel,Aluminum Alloy
Power: Pneumatic,electric
Structure: Control,Angle Stroke
Application: General,industrial
Standard Or Nonstandard: Standard
Type: Control,pneumatic
Standard: DIN,ANSI,BS,ASTM
Highlight:

Samson electropneumatic positioner HART 4-20mA

,

smart positioner for pneumatic actuators

,

electropneumatic positioner with HART protocol

Basic Infomation
Brand Name: Samson
Model Number: 3730-3
Payment & Shipping Terms
Packaging Details: carton or wooden crate, 30 × 30 × 30 cm
Delivery Time: 5~8 weeks
Payment Terms: T/T
Supply Ability: 2,750 units per year
Product Description

Product Overview

The Samson 3730-3 is a digitally enhanced electropneumatic positioner that uses HART communication to manage pneumatic control valves. It operates with single-acting and double-acting actuators, both linear and rotary. The device compares the control system's 4-20 mA command against the actual valve travel or angle, then delivers a corresponding pneumatic signal to the actuator.

Self-calibration is automatic, adapting to the valve and actuator without manual intervention. The travel sensor is gear-free, eliminating the mechanical wear that affects traditional gear-based sensors. Four initialization modes are available, including a substitution mode for emergency start-up while the plant is running, without moving the valve.

All parameters reside in non-volatile EEPROM, safe from power failure. The two-wire system draws a low electrical load of 410 Ω. The LCD can be read from any mounting position thanks to a rotatable display direction. Configuration is done through a single-knob menu or via PC using TROVIS-VIEW software over the SSP serial interface.

Technical Specifications

 
 
Parameter Specification
Brand Samson
Communication Protocol HART
Input Signal 4 to 20 mA
Data Interface Wired
Diagnostics EXPERTplus valve diagnostics; Self-diagnostics; NAMUR NE 107 status
Supply Pressure 1.4 to 7 bar (20 to 105 psi)
Mounting Type Linear and Rotary actuators; Single and Double-acting
Valve Travel 3.6 to 300 mm
Opening Angle 24 to 100°
Operating Temperature -20 to +80°C
Enclosure Protection IP 66 / NEMA 4X
Housing Material Die-cast aluminum or stainless steel
Electrical Load 410 Ω at 20 mA
Minimum Current 3.6 mA for display; 3.8 mA for operation
Signal Pressure (Output) 0 bar to supply pressure; software-limited to 1.4/2.4/3.7 bar
Air Quality ISO 8573-1: max particle size/density Class 4, oil content Class 3, dew point Class 3
Certifications SIL capable; ATEX, IECEx, FM, CSA (depending on version)
Communication Software TROVIS-VIEW; DTM available

Application Industry

The Samson 3730-3 is used in chemical and petrochemical processing, power generation, pulp and paper, and general industrial automation. It is suitable for challenging transit times, challenging ambient conditions, throttling service, and applications requiring an external travel sensor. The integrated EXPERTplus diagnostics enable predictive maintenance for control valves.

Common Problems

  • Initialization error: Check supply pressure is within 1.4~7 bar. Verify the travel sensor is properly connected and the valve is not stuck.

  • Zero calibration error: The zero point is out of range. Check mounting and re-initialize the positioner.

  • Communication status error: Check HART communication wiring. Verify the load resistance is within specification (410 Ω). Inspect for overrun, framing, or parity errors in the communication buffer.

  • Positioner does not respond to input signal: Check supply pressure and pneumatic connections. Verify that the device is in the correct operating mode.

  • Valve does not reach end position: Verify that the output pressure limitation setting is not too low. Check for air leaks in tubing and actuator.

  • Temperature sensor failure: Temperature measurement failed. Accuracy of diagnostics may be reduced. Contact service for replacement.

Replacement Models

The Samson 3730-3 will be discontinued in the near future. The direct replacement is the TROVIS 3730-3, which is the next-generation smart positioner with HART 7 communication and optimized EXPERTplus valve diagnostics. The TROVIS 3730-3 features a contactless internal position sensor, half the air consumption of previous versions, and uses the same mounting parts as the 373x series. Other models in the series include the 3730-4 (Profibus) and 3730-5 (FOUNDATION Fieldbus). For cross-vendor alternatives, the Neles ND9000 series and Masoneilan SVI-II series are frequently cited as direct competitors.

Ratings & Review

Overall Rating

5.0
Based on 50 reviews for this supplier

Rating Snapshot

The following is the distribution of all ratings
5 stars
100%
4 stars
0%
3 stars
0%
2 stars
0%
1 stars
0%

All Reviews

A
Anggoro Fikri
Indonesia Jan 31.2025
good quality
Recommended Products
Get in touch with us
Contact Person : Mr. Edward Zhao
Tel : +8615000725058
Characters Remaining(20/3000)