logo

HART Communication Digital Valve Positioner Package with 4-20 mA DC Input Signal and Stainless Steel Aluminum Alloy Construction

1
MOQ
US $2,400 ~ $5,400
Price
HART Communication Digital Valve Positioner Package with 4-20 mA DC Input Signal and Stainless Steel Aluminum Alloy Construction
Features Gallery Product Description Ratings & Review Request A Quote
Features
Specifications
Material: Stainless Steel,Aluminum Alloy
Media: Gas
Power: Electric
Pressure: Medium Pressure,Low Pressure
Structure: Control
Temperature Of Media: Normal Temperature,-35℃~+45℃
Application: Industrial,Food Dairy Beverage Beer Wine Biology Chemical Industry.
Standard Or Nonstandard: Standard
Type: Control
Standard: DIN,ANSI,ASTM
Size: Standard
Highlight:

DVC2000 Digital Valve Positioner

,

Fisher Digital Valve Positioner Package

,

Pneumatic Control Valve Positioner

Basic Infomation
Brand Name: Fisher
Model Number: DVC2000
Payment & Shipping Terms
Packaging Details: carton or wooden crate, 30 × 30 × 30 cm
Delivery Time: 5~8 weeks
Payment Terms: T/T
Supply Ability: 2,800 units per year
Product Description

Product Overview
The Fisher DVC2000 Digital Valve Positioner Package is a fully assembled valve control package that pairs the DVC2000 positioner with a pneumatic control valve actuator to form a complete, ready-to-install system. It arrives with the positioner body, mounting bracket, feedback linkage, pressure gauges, filter regulator, tubing, fittings, terminal block, manual, calibration certificate, and a 12-month warranty. Because the package is pre-built and pre-tested at the factory, plant teams avoid the time-consuming work of sourcing separate parts and matching them on site. The unit accepts a 4-20 mA DC command signal and uses HART communication for setup, calibration, and diagnostic access. It delivers precise pneumatic output for valve stroke control and includes travel feedback for continuous position verification. Local adjustment, auto calibration, and diagnostic alarms help keep the control loop stable during routine operation.
The enclosure is engineered for industrial service and shields internal electronics from dust, water, and mechanical vibration. It operates reliably across a wide ambient temperature range and accepts standard instrument air supply pressures. Control choices include local calibration, remote configuration, and diagnostic reporting. The package meets common industrial standards and is suitable for chemical, petrochemical, oil and gas, power, water, pharmaceutical, food, and general process industries. Its modular construction reduces maintenance effort and supports long-term reliability with straightforward spare parts planning. Every package is backed by a 12-month warranty.

Technical Specifications

 
 
Parameter Specification
Product Type Digital Valve Positioner Package
Model DVC2000
Input Signal 4-20 mA DC
Communication Protocol HART
Supply Pressure 20-100 psi
Output Signal Pneumatic relay output
Enclosure Rating NEMA 4X / IP66
Operating Temperature -40°C to +85°C
Diagnostics ValveLink compatible diagnostics
Feedback Travel feedback assembly
Mounting Standard mounting bracket
Certification Industrial standard compliance
Warranty 12 months
Application Pneumatic valve control
Media Air / Gas
Power Loop powered / electric
Manual Operation Local adjustment and calibration
Process Connection None
Valve Type Pneumatic control valve
Size Standard

Application Industry

  1. Chemical processing

  2. Petrochemical refining

  3. Oil and gas production

  4. Power generation

  5. Water and wastewater treatment

  6. Pharmaceutical manufacturing

  7. Food and beverage processing

  8. Pulp and paper
    These sectors depend on accurate valve positioning, stable HART communication, and dependable diagnostics. The DVC2000 package performs well in humid, dusty, and vibrating plant environments when installed and maintained correctly. It supports flow, pressure, and level control loops that use pneumatic control valves.

Common Problems

  1. Valve does not move: check 4-20 mA signal, air supply, and actuator linkage.

  2. HART communication failure: verify loop wiring, power, and device address.

  3. Valve hunting: inspect tuning, air supply stability, and actuator sizing.

  4. Air leakage: check fittings, gaskets, and relay assembly.

  5. Incorrect feedback: inspect feedback linkage, magnet, and calibration.

  6. Diagnostic alarm: review ValveLink data, supply pressure, and valve friction.

  7. Zero drift: confirm mounting stability and recalibrate.

  8. Moisture in air line: service filter regulator and install dryer if needed.

  9. Manual override issue: check bypass, linkage, and actuator spring.

  10. Output pressure error: inspect I/P converter, nozzle, and relay.
    All units are backed by a 12-month warranty.

Replacement Models

  1. Fisher DVC6000

  2. Fisher DVC6200

  3. Fisher DVC6010

  4. Flowserve Logix 520MD

  5. Masoneilan SVI1000

  6. Neles ND9000

  7. Samson 3730-3

  8. Rotork YTC Series
    Selection note: confirm mounting standard, travel range, input signal, supply pressure, communication protocol, and actuator compatibility.

Ratings & Review

Overall Rating

5.0
Based on 50 reviews for this supplier

Rating Snapshot

The following is the distribution of all ratings
5 stars
100%
4 stars
0%
3 stars
0%
2 stars
0%
1 stars
0%

All Reviews

A
Anggoro Fikri
Indonesia Jan 31.2025
good quality
Recommended Products
Get in touch with us
Contact Person : Mr. Edward Zhao
Tel : +8615000725058
Characters Remaining(20/3000)