Product Overview
The AUMA SA Series Multi-Turn Electric Actuator Package is an all-inclusive automation system engineered to integrate seamlessly with your industrial valves, arriving pre-assembled and fully calibrated from the factory. This package puts the actuator, mounting flange, limit switches, and terminal box into one single-source solution, eliminating the engineering hassle of sourcing separate components and ensuring perfect mechanical compatibility. As a result, on-site installation and commissioning times are drastically cut down, allowing your system to be operational much faster. The package delivers robust torque up to 1,000 Nm and selectable output speeds of 12 to 72 rpm. Feedback is highly reliable through mechanical limit and torque switches, while the built-in handwheel guarantees safe manual override during power failures. Furthermore, the system supports various control protocols, including Profibus DP and Modbus RTU, ensuring direct and reliable integration into your DCS.
Built to thrive in demanding operational environments, the SA Series package is encased in a rugged cast aluminum housing that delivers IP67 or IP68 protection. It performs exceptionally well in ambient temperatures ranging from -35°C to +45°C. The unit complies with CE regulations and can be supplied with ATEX certification for explosive atmospheres. It is heavily utilized in water treatment plants, chemical processing facilities, power generation stations, and oil and gas operations. The hardened gear train provides exceptional durability under high cycling rates, while accessible terminal compartments simplify field wiring and maintenance. With advanced diagnostic capabilities, operators can continuously monitor system health and address potential issues early, thereby extending the lifespan of the actuator and maximizing plant safety.
2. Technical Specifications
| Parameter | Specification |
|---|---|
| Product Type | Multi-Turn Electric Actuator Package |
| Model | SA Series |
| Torque Range | 20 Nm to 1,000 Nm |
| Output Speed | 12 to 72 rpm |
| Motor Type | Three-phase AC or Single-phase AC |
| Duty Cycle | S4 motor duty, 50% duty |
| Protection Class | IP67 / IP68 |
| Input Signal | 24 VDC / 110 VAC / 220 VAC |
| Output Signal | 4-20 mA / 0-10 V |
| Communication Protocol | Profibus DP / Modbus RTU / HART |
| Manual Operation | Handwheel with manual override |
| Ambient Temperature | -35°C to +45°C |
| Enclosure Material | Cast aluminum alloy |
| Mounting Standard | ISO 5210 / ISO 5211 |
3. Application Industry
Water and Wastewater Treatment: Provides accurate flow regulation and reliable pump isolation in municipal systems.
Chemical and Petrochemical: Manages corrosive media safely and executes rapid emergency shutdowns.
Power Generation: Automates boiler feedwater, cooling circuits, and main steam lines.
Oil and Gas: Supports robust pipeline flow management and wellhead automation.
Food and Beverage: Ensures sanitary valve automation, maintaining strict hygiene during CIP cycles.
Pulp and Paper: Delivers reliable isolation for harsh chemical pulping processes.
These industries demand continuous operation under extreme weather, high vibration, and remote command scenarios. The rugged design of the SA Series guarantees stable performance and operational integrity in the most severe conditions.
4. Common Problems
Actuator fails to respond to remote commands: Check the control power fuse, verify wiring connections, and confirm the incoming signal integrity.
Motor overheats during continuous operation: Ensure duty cycle limits are not exceeded, verify ambient temperature, and inspect for valve binding.
Torque switch trips unexpectedly: Check for physical obstructions inside the valve or recalibrate the torque limiting settings.
Handwheel is stiff or difficult to turn: Inspect the gear train lubrication and confirm the manual override lever is fully engaged.
Incorrect position feedback signal: Recalibrate the limit switches and check the feedback wiring loop for loose connections.
Moisture detected inside the enclosure: Inspect cover gaskets, O-rings, and cable glands for wear or improper sealing.
Network communication failure: Check the bus termination resistors, verify baud rate settings, and inspect cable shielding.
Actuator motor runs but valve stem does not move: Verify the integrity of the stem coupling and inspect the valve stem for stripping or damage.
5. Replacement Models
AUMA SAEx Series
Rotork IQ3 Series
SIPOS 7 Series
Limitorque MX Series
AUMA SQ Series
Rotork IQT Series
Note: Always verify that the mounting flange (ISO 5210/5211), torque rating, output speed, and communication protocol match your original equipment specifications.
Overall Rating
Rating Snapshot
The following is the distribution of all ratingsAll Reviews