The SAMSON 3731 series is designed to control the position of pneumatic control valves in industrial process applications. By comparing the control reference with the actual valve travel or rotary angle, the positioner adjusts pneumatic output pressure to move the actuator toward the required position.
The series includes different communication versions. For example, the Type 3731-3 uses a 4–20 mA input with HART communication, while the Type 3731-5 communicates via FOUNDATION Fieldbus. This makes it important to identify the exact version before ordering or planning a replacement.
Depending on the model and configuration, the 3731 can be installed on compatible linear or rotary actuators. Automatic initialization and local operation support commissioning, adjustment and maintenance work.
| Parameter | Specification |
|---|---|
| Product Family | SAMSON 3731 Series |
| Product Type | Electropneumatic Positioner |
| Application | Pneumatic control valves |
| Linear Travel Range | 3.6–200 mm, depending on version and mounting |
| Rotary Actuator Range | 24°–100° |
| Actuator Action | Single-acting or double-acting, depending on version |
| 3731-3 Input Signal | 4–20 mA, two-wire |
| 3731-3 Communication | HART |
| 3731-5 Communication | FOUNDATION Fieldbus |
| Initialization | Automatic initialization |
| Local Operation | LCD and menu-driven operation |
| Diagnostics | Monitoring and diagnostic functions; EXPERTplus available on specified versions |
| Mounting | SAMSON direct mounting, IEC 60534-6-1 or VDI/VDE 3845 interfaces, as applicable |
The table covers key family-level information. Individual specifications and approvals must be confirmed against the exact 3731 version and type code.
Oil and gas production and processing
Refining and petrochemical operations
Chemical manufacturing
Thermal and other power generation
Water and wastewater treatment
General industrial process control
Incorrect position feedback
Check the positioner initialization, mechanical coupling and valve travel settings. Incorrect mounting or linkage can lead to inaccurate position control.
Slow or inconsistent valve response
Inspect the instrument air supply, pneumatic tubing, actuator condition and valve friction. The positioner should be checked only after the mechanical and air-supply conditions are verified.
Communication mismatch
Confirm whether the installed unit is a HART or FOUNDATION Fieldbus version. The communication protocol must match the control system and project design.
Replacement model uncertainty
The 3731 type number alone may not identify every required option. Check the complete type code, nameplate, mounting arrangement and approval requirements.
Depending on the existing installation, the following options may be evaluated:
SAMSON Type 3731-3 — HART communication version
SAMSON Type 3731-5 — FOUNDATION Fieldbus communication version
SAMSON Type 3730 series — alternative SAMSON positioner family for selected installations
These models should not be treated as automatic drop-in replacements. Confirm communication protocol, actuator action, mounting dimensions, electrical connections and hazardous-area approvals before making a substitution.
Industrial valve positioner sourcing
Support with model and type-code identification
Assistance checking communication and mounting requirements
Spare-part and project procurement support
International delivery coordination
Our team can help review the original device information and clarify the required configuration before quotation.
Availability is subject to the selected 3731 version and its options. Lead time can differ between HART and FOUNDATION Fieldbus configurations.
Please send the full model designation, type code and quantity. We will check availability and confirm the estimated delivery schedule.
For a faster quotation, please provide:
Product: SAMSON 3731 Valve Positioner
Exact Model: 3731-3 / 3731-5 / Other
Complete Type Code
Required Quantity
Communication Protocol
Valve and Actuator Information
Mounting Requirements
Destination Country
Expected Delivery Date
Nameplate Photo or Existing Part Number
If the exact version is unknown, send us a photo of the installed positioner and its nameplate for identification.
Overall Rating
Rating Snapshot
The following is the distribution of all ratingsAll Reviews