In a custody transfer installation, flow measurement is not just about reading a meter. The system must also process pressure, temperature and other measurement signals, apply the required calculation standards, and maintain reliable records of the transferred quantity.
The FloBoss S600+ is a panel-mounted flow computer developed for hydrocarbon liquid and gas measurement. It is designed for fiscal measurement, custody transfer, pipeline measurement and meter proving, where calculation integrity and data handling are important to the operation.
The S600+ can handle both gas and liquid measurement applications. With optional expansion modules, it supports up to ten measurement streams and up to two stations. A single unit can be configured for a combination of liquid and gas streams, making it suitable for metering systems that handle different hydrocarbon products.
Its calculation capability covers widely used industry standards, including AGA, ISO, GPA and GERG for gas measurement, as well as API and ASTM standards for liquid applications. Supported meter technologies include turbine, ultrasonic, Coriolis and positive displacement meters, along with differential-pressure primary elements such as orifice plates, Venturi tubes, Annubar and V-Cone devices.
For applications where measurement records need to be retained and reviewed, the S600+ provides extended data logging and event archiving. Its 64-bit double-precision calculations and three-location storage of cumulative totals are designed to support the integrity of metering data.
| Parameter | Specification |
|---|---|
| Product Name | FloBoss S600+ |
| Product Type | Panel-Mounted Fiscal Flow Computer |
| Measurement Medium | Hydrocarbon gases and liquids |
| Mounting | Panel mounting, indoor use |
| Measurement Streams | Up to 10 with optional expansion modules |
| Measurement Stations | Up to 2 |
| Calculation Precision | 64-bit double-precision floating point |
| Totalization Data Storage | Three separate memory locations (Tri-reg format) |
| Gas Measurement Standards | AGA, ISO, GPA, GERG and other supported standards |
| Liquid Measurement Standards | API, ASTM, GPA and NORSOK standards |
| Supported Meter Technologies | Turbine, ultrasonic, Coriolis, positive displacement, orifice, Venturi, Annubar and V-Cone |
| Display | 8-line LCD |
| Keypad | 29-key front-panel keypad |
| Ethernet | 2 independent 10/100baseT ports |
| Serial Communication | 2 × RS-232 and 7 × RS-422/RS-485 ports |
| USB | USB 2.0 |
| HART Interface | Optional 12-channel HART module |
| Configuration Software | Config600 Lite, Config600 Lite+ and Config600 Pro |
The number of streams, HART capability and available I/O depend on the installed expansion modules and configuration.
Oil and Gas Measurement
Used in gas production, processing and transmission facilities where flow quantities must be calculated and recorded for operational or commercial purposes.
Natural Gas Custody Transfer
Suitable for metering systems that require gas flow calculation based on configured measurement standards and input data from field instruments.
Crude Oil and Refined Product Terminals
Can be configured for liquid hydrocarbon measurement, including crude oil, refined products, LPG and NGL applications.
Pipeline Metering Stations
Supports single-stream and multi-stream measurement arrangements for pipeline transportation and transfer facilities.
LNG and Hydrocarbon Processing
May be applied in suitable hydrocarbon measurement systems where the required meter technology, calculation method and instrument interfaces are supported by the selected configuration.
Measured totals do not match the expected transfer records
Differences may result from incorrect meter factors, input signals, base conditions or calculation settings. Review the configured measurement parameters and compare the flow computer data with the connected meter and field instruments.
A measurement stream is not updating
Check the relevant pulse, analog or communication input, together with the channel assignment and configuration file. The cause may be in the field instrument, wiring or I/O module rather than the flow computer itself.
Communication with an ultrasonic or Coriolis meter is interrupted
Verify the communication interface, protocol settings, wiring and meter driver configuration. The S600+ supports different intelligent meter interfaces, but the selected interface must match the connected instrument.
Historical reports or event records are incomplete
Review the archive configuration, storage settings, system time and report setup. Exported data should also be checked against the requirements of the site's measurement and reporting procedures.
The appropriate replacement depends on the installed hardware, configuration files, I/O modules and measurement application.
FloBoss S600+: The direct model to consider when replacing an existing S600+ unit. Confirm the hardware revision, I/O arrangement and configuration requirements.
FloBoss S600: The S600+ is designed to be fully backward-compatible with the previous S600 model. Existing configurations and familiar tools can be retained in supported conversion projects.
Other flow computers: A different platform should only be considered after reviewing measurement standards, meter interfaces, I/O capacity, communication protocols, reporting requirements and project approval conditions.
For an S600-to-S600+ conversion, verify the existing configuration and hardware arrangement before ordering.
Flow computers are configuration-dependent instruments. Selecting the correct model requires more than checking the product name.
We support industrial buyers with:
Sourcing of FloBoss flow computers and related instrumentation
Model and part-number verification
Assistance checking I/O modules and communication requirements
Support for replacement, spare-part and project procurement
Coordination of international delivery
Providing the existing unit's nameplate and configuration details helps us review the requested model before quotation.
Availability depends on the requested S600+ hardware, I/O modules and configuration requirements. Standard units and specially configured systems may have different lead times.
Please provide the model or part number, required quantity and application details. We will check the available supply options and confirm the estimated delivery schedule.
Export packing and international shipment can be arranged according to the destination and project requirements.