| Features | Easy, Simple, Accurate |
|---|---|
| Condition | New |
| Air Delivery | 280 SLPM @ 30psi |
| Model Number | SVI II |
| Air Supply Pressure | Single-Acting(1.4 To 6.9 Bar), Double-Acting(1.4 To 10.3 Bar) |
| Repeatability | +/- 0.3 Percent Full Span |
|---|---|
| Pneumatics | Air Or Sweet Natural Gas – Regulated And Filtered |
| Linearity | +/- 1 Percent Full Scale |
| Operating Temperature | -50°C To +85°C |
| Model Number | SVI II |
| Condition | New |
|---|---|
| Accuracy | +/- 0.5 Percent Full Span |
| Model Number | SVI II |
| Supply Pressure | 20 To 150psi |
| Linearity | +/- 1 Percent Full Scale |
| Condition | New |
|---|---|
| Type | Digital Valve Positioner |
| Linearity | +/- 1 Percent Full Scale |
| Hysteresis + DeadBand | +/- 0.3 Percent Full Span |
| Model Number | SVI II |
| Condition | New |
|---|---|
| Pneumatics Action | Single Or Double Acting, Fail Safe,Rotary And Linear |
| Materials | Copper-free Aluminum Housing |
| Air Supply Pressure | Single-Acting(1.4 To 6.9 Bar), Double-Acting(1.4 To 10.3 Bar) |
| Repeatability | +/- 0.3 Percent Full Span |
| Pneumatics | Air Or Sweet Natural Gas – Regulated And Filtered |
|---|---|
| Hysteresis + DeadBand | +/- 0.3 Percent Full Span |
| Operating Temperature | -50°C To +85°C |
| Linearity | +/- 1 Percent Full Scale |
| Materials | Copper-free Aluminum Housing |
| Operating Temperature | -55°C To +85°C |
|---|---|
| Signal - Communication | HART 7 Over 4-20mA |
| Construction / Materials | Copper-free Aluminum Housing |
| Model Number | SVI3 Digital Valve Positioner |
| Pneumatics Action | Single Acting, Fail Safe;Rotary And Linear |
| Accuracy | +/- 0.5 Percent Full Span |
|---|---|
| Minimum Current Signal | 3.2 MA |
| Power Supply | 4-20 MA |
| Diagnostics | Standard Diagnostics,Advanced Diagnostics |
| Materials | Copper-free Aluminum Housing |
| Pneumatics Action | Single Or Double Acting, Fail Safe,Rotary And Linear |
|---|---|
| Materials | Copper-free Aluminum Housing |
| Air Supply Pressure | Single-Acting(1.4 To 6.9 Bar), Double-Acting(1.4 To 10.3 Bar) |
| Repeatability | +/- 0.3 Percent Full Span |
| Minimum Current Signal | 3.2 MA |
| Area Classification | Intrinsically Safe, Explosion Proof, Dust Ignition Proof, Flame Proof, Non-incendive, Type N |
|---|---|
| Certifications | CSA, FM, ATEX, KGS, Peso, CIMFR, NEPSI, TIIS, Ukraine Metrology, Belarus Metrology, Kazakhstan Metrology, IECEx, INMETRO, CUTR |
| Communication Protocol | HART®, 4-20mA Analog |
| Data Interface | Wired |
| Diagnostics | Yes |