| Positioning Accuracy | Typically ±0.5% |
|---|---|
| Valve Stroke Range | Typically 20mm, 40mm, 60mm, Or 100mm |
| Output Signal | Typically 4-20mA Or 0-10VDC |
| Mounting | Vertical Or Suspended Mounting Options |
| Operating Temperature Range | -40°C To +85°C |
| Accessories | Overload Protection, Manual Operation, Protective Cover, And Transition Plate |
|---|---|
| Positioning Accuracy | Typically ±0.5% |
| Valve Stroke Range | Typically 20mm, 40mm, 60mm, Or 100mm |
| Mounting | Vertical Or Suspended Mounting Options |
| Output Signal | Typically 4-20mA Or 0-10VDC |
| Accessories | Overload Protection, Manual Operation, Protective Cover, And Transition Plate |
|---|---|
| Positioning Accuracy | Typically ±0.5% |
| Operating Temperature Range | -40°C To +85°C |
| Mounting | Vertical Or Suspended Mounting Options |
| Power Supply Voltage | 24VDC Or 110-240VAC |
| Input Signal | 4~20mA DC |
|---|---|
| Impedance | 500Ω (20mA DC) |
| Supply Pressure | 0.14~0.7MPa |
| Stroke | Linear Type:10~150mm, Rotary Type:0~90º |
| Air Connection | PT1/4, NPT1/4 |
| Deadband Adjustment | Adjustable Deadband To Accommodate Different Applications |
|---|---|
| Digital Communication Interface | Optional RS485 Modbus RTU Or FOUNDATION Fieldbus Interface |
| Protection Level | IP66 |
| Output Signal | 4-20mA DC, HART Protocol, Etc |
| Local Display | 4-digit LCD Screen, Which Can Display Current Analog Input Value, Output Value, Set Value, And Device Status Information |
| Safety Features | Overvoltage Protection, Reverse Polarity Protection, Short-circuit Protection |
|---|---|
| Programmability | Programmable Through FoxCom Or PC Software |
| Optional Accessories | Pressure Modules, Temperature Sensors, Communication Cables, PC Software |
| Power Output | 24V DC Nominal, 20 MA Max |
| Ramp Function | User-defined Ramp Function With Adjustable Time |
| Measurement Range | 0-24 MA DC |
|---|---|
| Display | LCD Display, 2 Lines X 16 Characters |
| Output Resolution | 0.001 MA |
| Battery Life | Approx. 20 Hours Continuous Use At 20 MA Output |
| Accuracy | 0.025% Full Scale |
| Safety Features | Overvoltage Protection, Reverse Polarity Protection, Short-circuit Protection |
|---|---|
| Ramp Function | User-defined Ramp Function With Adjustable Time |
| Optional Accessories | Pressure Modules, Temperature Sensors, Communication Cables, PC Software |
| Step Function | 25% Step, 100% Step, User-defined Step |
| Certifications | CE, CSA, FM, ATEX, IECEx, GOST-R |
| Application | General |
|---|---|
| Material | Casting |
| Temperature Of Media | Medium Temperature |
| Pressure | Medium Pressure |
| Power | Pneumatic |
| Product Name | Original Flowserve Positioner UAS Logix 3200 MD Pneumatic Digital Valve Positioner With Lot Of Stock |
|---|---|
| Model | SA/CL |
| Temperature Of Media | High Temperature |
| Pressure | High Pressure |
| Operating Temperature | -20 To 55°C (-4 To 122°F) |