| Material | 316L , AlloyC |
|---|---|
| Process Temperature | -70°C...400°C (-94°F...752°F) |
| Max. Measurement Distance | 4000m (13.123ft) H2O |
| Max. Overpressure Limit | 600 Bar (9000 Psi) |
| Measuring Cell | 400 Mbar...400 Bar(5.8 Psi...6000 Psi)relative/ Absolute |
| Material | 316L , AlloyC |
|---|---|
| Process Temperature | -70°C...400°C (-94°F...752°F) |
| Max. Measurement Distance | 4000m (13.123ft) H2O |
| Max. Overpressure Limit | 600 Bar (9000 Psi) |
| Measuring Cell | 400 Mbar...400 Bar(5.8 Psi...6000 Psi)relative/ Absolute |
| Ambient Temperature | -50...+80 °C (-58...+176 °F) |
|---|---|
| Sensor Length | Rod Probe: 10 M /Rope Probe: 45 M /Coaxial Probe: 6 M |
| Communication | 4...20 MA HART PROFIBUS PA FOUNDATION Fieldbus |
| Process Pressure/max. Overpressure Limit | Vacuum...400 Bar (Vacuum...5800 Psi) |
| Measuring Principle | Guided Radar |
| Ambient Temperature | -50...+80 °C (-58...+176 °F) |
|---|---|
| Sensor Length | Rod Probe: 10 M /Rope Probe: 45 M /Coaxial Probe: 6 M |
| Communication | 4...20 MA HART PROFIBUS PA FOUNDATION Fieldbus |
| Process Pressure/max. Overpressure Limit | Vacuum...400 Bar (Vacuum...5800 Psi) |
| Material | Stainless Steel |
| Ambient Temperature | -50...+80 °C (-58...+176 °F) |
|---|---|
| Sensor Length | Rod Probe: 10 M /Rope Probe: 45 M /Coaxial Probe: 6 M |
| Communication | 4...20 MA HART PROFIBUS PA FOUNDATION Fieldbus |
| Process Pressure/max. Overpressure Limit | Vacuum...400 Bar (Vacuum...5800 Psi) |
| Measuring Principle | Guided Radar |
| Ambient Operating Temperature | -20 °C To +55 °C (-4 °F To +131 °F) |
|---|---|
| Dimensions | 100.5*108.5*69.7mm |
| Digital Communication | HART Protocol (standard), Profibus DP (optional) |
| Power Supply | 100-230 V AC ±10%, 50/60 Hz, Or 24 V DC |
| Enclosure Rating | IP65 |
| Dimensions | 100.5*108.5*69.7mm |
|---|---|
| Digital Communication | HART Protocol (standard), Profibus DP (optional) |
| Ambient Operating Temperature | -20 °C To +55 °C (-4 °F To +131 °F) |
| Accuracy | ±0.01 PH, ±0.05% Of Range For Conductivity |
| Power Supply | 100-230 V AC ±10%, 50/60 Hz, Or 24 V DC |
| Measurement Range | Up To 2000 Psi (137,89 Bar) Differential |
|---|---|
| Communication | Protocol4-20 MA HART, WirelessHART, FOUNDATION,Fieldbus, PROFIBUS |
| Diagnostics | Basic Diagnostics, Loop Integrity |
| Output | Differential Pressure, Scaled Variable |
| Rangedown | Up To 150:1 |
| Measurement Range | Up To 2000 Psi (137,89 Bar) Differential |
|---|---|
| Communication | Protocol4-20 MA HART, WirelessHART, FOUNDATION,Fieldbus, PROFIBUS |
| Diagnostics | Basic Diagnostics, Loop Integrity |
| Output | Differential Pressure, Scaled Variable |
| Rangedown | Up To 150:1 |
| Type | Vortex Flowmeter |
|---|---|
| Material | Stainless Steel |
| Process Pressure | Max. 100 Barg/ 1450 Psig |
| Digital Outputs | FOUNDATION Fieldbus, HART , Profibus-PA |
| Analogue Outputs | 4~20 MA |