| Power Supply | Loop Powered From 4-20mA Control Signal |
|---|---|
| Load Voltage | 11.0 VDC At 20 MA DC / 10.0 VDC At 4 MA DC |
| Acting Type | Single Or Double |
| Supply Medium | Air Or Nitrogen |
| Digital Communicatin | HART 7 |
| Set Point | 4 To 20 MA |
|---|---|
| Valve Travel | 3.6 To 300 Mm |
| Opening Angle | 24 To 100° |
| Material | Aluminum |
| Packaging Details | Export wooden boxes for foreign trade, IPPC sterilized wooden boxes and plywood boxes for export customs inspection-free. Size: 60*30*40 (cm) |
| Set Point | 4 To 20 MA |
|---|---|
| Valve Travel | 3.6 To 300 Mm |
| Opening Angle | 24 To 100° |
| Material | Aluminum |
| Packaging Details | Export wooden boxes for foreign trade, IPPC sterilized wooden boxes and plywood boxes for export customs inspection-free. Size: 60*30*40 (cm) |
| Colour | Grey |
|---|---|
| Mode Of Action | Double Acting |
| Repeatability | ≤0 .25% |
| Temperature | -40 ° +85° |
| Supply Media | Air Oil Gas |
| Acting Type | Single-Acting (03 Suffix) / Double-Acting (06 Suffix) |
|---|---|
| Feedback Type | Standard (HX) / Enhanced Precision (HE) |
| Input Signal | 4-20mA + HART Communication Protocol |
| Supply Pressure | 1.4-8 Bar (0.14-0.8 MPa) |
| Operating Temperature | -40°C To +80°C (Standard Version) |
| Communication Port Protocol | HART, 4...20 MA Profibus FOUNDATION Fieldbus |
|---|---|
| Pneumatic Connection Type | 0.25 Inch 18 NPT G 1/4 |
| Input Pressure | 1.4...6 Bar |
| Stroke Range | 8...260 Mm |
| Maximum Hysteresis | 0.3 % |
| Input Signal | 4-20 MA DC |
|---|---|
| Linearity | ≤ ±0.75% Of Span |
| Housing Material | Aluminum Or Stainless Steel |
| Ambient Temperature | -40 °C To +80 °C |
| Repeatability | ≤ ±0.3% |
| Input | 4-20 MA DC (resistance 300 Ω) |
|---|---|
| Communication | HART6 (AVP102) |
| Air Supply | 140-700 KPa |
| Air Use | 4 L/min (N) Single-acting At Balance |
| Max Flow | 110 L/min (N) Single-acting At 400 KPa |
| Communication Protocol | HART 7 |
|---|---|
| Maximum Output Pressure | 145 Psig |
| Process Control | Flow, Pressure, Temperature, Level |
| Input Signal | 4-20 MA DC, 24 VDC |
| Media Supply | Air Or Natural Gas |
| Diagnostics | Yes |
|---|---|
| Mounting Type | Integral Mounted |
| Supply Media | Air, Non Corrosive Gas |
| Process Control | Flow Pressure Temperature Level |
| Operating Temperature | Standard Temperature, High Temperature |