| Type | GX |
|---|---|
| Certified | CRN, CUTR, Fugitive Emissions, PED, SIL Compliance |
| Valve Size | NPS 1/2, NPS 3/4, NPS 1, NPS 1-1/2, NPS 2, NPS 3, NPS 4, NPS 6 |
| Flow Characteristic | Balance Percentage, Linearity, Characterization |
| Material | Carbon Steel, Stainless Steel, Double-sided, Alloy |
| Product Name | China Pressure Balanced Cage Control Valve |
|---|---|
| Nominal Pressure | PN16/25/40/63/100 |
| Flow Characteristics | Equal Percentage, Linear, Quick-opening |
| Leakage Class | ANSI B16.104: IV,V,VI |
| Nominal Diameter | DN40 To DN400 |
| Product Name | 3213 Electric Globe Valve With DIN Version DN 15 To DN 50 Valve Size With Fisher DVC2000 Digital Valve Positioner |
|---|---|
| Brand | SAMSON |
| Model | 3213 Electric Globe Valve |
| Matrial | Alloy/Steel |
| Valve Style | Globe Valve |
| Name | 301K/332K Control Valve Straight Through Ball Valve For Valves Koso With Flowserve 3800 Series Positioner |
|---|---|
| Type | 301K |
| Full Bore Size | 1/2"(15A) To 16"(400A) |
| Reduced Bore Size | 4" X3" To 18" X 16" |
| Rating | ANSI Class 150 To 300, JIS 10K To 40K |
| Product Name | China Pneumatic Bellows Control Valve |
|---|---|
| Nominal Diameter | DN15 ~ DN300 |
| Nominal Pressure | PN16/25/40/63/100 |
| Operating Temperature | -45℃~ 350℃ |
| Valve Body Material | Cast Steel, Chromium-molybdenum Steel, Stainless Steel |
| Name | Valve Positioner Digital Positioner LOGIX520MD+37 Control Valve Positioner For Flowserve |
|---|---|
| Brand | LOGIX |
| Model | LOGIX 520MD+37 |
| Sub-Type | Digital |
| Air Capacity | 20.8 To 30.6 Nm3 /h @ 4.1 Bar |
| Deadband Adjustment | Adjustable Deadband To Accommodate Different Applications |
|---|---|
| Digital Communication Interface | Optional RS485 Modbus RTU Or FOUNDATION Fieldbus Interface |
| Protection Level | IP66 |
| Output Signal | 4-20mA DC, HART Protocol, Etc |
| Local Display | 4-digit LCD Screen, Which Can Display Current Analog Input Value, Output Value, Set Value, And Device Status Information |
| Operating Temperature Range | -40℃ To 70℃ |
|---|---|
| Digital Communication Interface | Optional RS485 Modbus RTU Or FOUNDATION Fieldbus Interface |
| Protection Level | IP66 |
| Deadband Adjustment | Adjustable Deadband To Accommodate Different Applications |
| Diagnostic Function | It Can Automatically Detect Faults And Device Status, And Provide Warning And Fault Prompt Information |
| Supply Pressure | 20 To 150psi |
|---|---|
| Repeatability | +/- 0.3 Percent Full Span |
| Accuracy | +/- 0.5 Percent Full Span |
| Pneumatics Action | Single Or Double Acting, Fail Safe,Rotary And Linear |
| Minimum Current Signal | 3.2 MA |
| Diagnostic Functions | Provides Status Reports And Fault Information, Supports Equipment Management And Maintenance |
|---|---|
| Linearity | Less Than 0.5% Of The Maximum Travel Value |
| Zero Point Drift | Less Than 0.1% Of The Maximum Travel Value |
| Material | Aluminum Alloy Or Stainless Steel |
| Suitable Media | Non-corrosive Media Such As Liquids, Gases, And Steam |