| Rated Flow Coefficient | Maximum CV Value Of 470 |
|---|---|
| Output Signal | 4-20mA, HART, PROFIBUS PA Or FOUNDATION Fieldbus |
| Valve Position Feedback | Provides Digital Position Feedback Through Hall Sensors Or Analog Position Feedback Through Potentiometers |
| Protection Rating | IP66/67 |
| Valve Travel Range | 10mm To 100mm |
| Temperature Of Media | High Temperature, Low Temperature, Medium Temperature, Normal Temperature |
|---|---|
| Warranty | 1 Year |
| Deviation | ≤1 % |
| Sensitivity | ≤0.1 % |
| Direction Of Action | Reversible |
| Sensitivity | ≤0.1 % |
|---|---|
| Warranty | 1 Year |
| Minimum Current | 3.6 MA For Display 3.8 MA For Operation |
| Temperature | ≤0.15 %/10 K |
| Customized Support | OEM |
| Protection Level | IP66 |
|---|---|
| Deadband Adjustment | Adjustable Deadband To Accommodate Different Applications |
| Diagnostic Function | It Can Automatically Detect Faults And Device Status, And Provide Warning And Fault Prompt Information |
| Local Display | 4-digit LCD Screen, Which Can Display Current Analog Input Value, Output Value, Set Value, And Device Status Information |
| Power Supply | 12-42V DC Power Supply |
| Input Signal | 4-20mA DC, 1-5V DC, 0-10V DC, HART Protocol, Etc |
|---|---|
| Protection Level | IP66 |
| Diagnostic Function | It Can Automatically Detect Faults And Device Status, And Provide Warning And Fault Prompt Information |
| Accuracy | Up To 0.075% Under Nominal Conditions |
| Deadband Adjustment | Adjustable Deadband To Accommodate Different Applications |
| Weight | 3.5KG |
|---|---|
| Maximum Output Torque | 600 Nm |
| Rated Pressure | Maximum 10 Bar |
| Display Screen | LCD Display Screen, Which Can Display Current Position, Power Status, And Other Information |
| Power Supply | 4V DC, 120V AC, Or 240V AC |
| Max Outlet Pressure | 145 Psig |
|---|---|
| Mounting Type | Integral Mounted |
| Operating Temperature | Standard Temperature, High Temperature |
| Position Control | Throttling Control, On/Off |
| Power Source | Local |
| Customized Support | OEM |
|---|---|
| Shell Material | Industrial Aluminum Housing |
| Type | Positioner |
| Supply Pressure | 150 PSI |
| Connection | Flange,Clamp,Thread, Sanity Thread |
| Shell Material | Industrial Aluminum Housing |
|---|---|
| Data Interface | Wired |
| Model Number | 3582i |
| Process Control | Flow, Pressure, Temperature, Level |
| Supply Media | Air |
| Ingress Protection | IP66 |
|---|---|
| Input Signal | 4 ~ 20 MA DC |
| Housing Material | Aluminum |
| Acting Type | Single / Double |
| Linearity | ± 0.5 % F.S. |