| Voltage Supply (maximum) | 30 VDC |
|---|---|
| Position Control | Throttling Control, On/Off |
| Humidity | 0-100% Non-condensing |
| Communication Protocol | HART |
| Shell Material | Industrial Aluminum Housing |
| Input Signal Options | 4-20 MA (analog), HART, FOUNDATION Fieldbus |
|---|---|
| Air Supply Pressure | 3-7 Bar |
| Protection Rating | IP66 |
| Accuracy | ≤ 0.25 % |
| Temperature Range | -52 °C To +85 °C (-62 °F To +185 °F) |
| Input Signal | 4-20 MA HART |
|---|---|
| Air Supply | 1.4 To 10.3 Bar (20 To 150 Psig) |
| Protection Rating | IP66 |
| Operating Temperature | -40°C To 80°C (-40°F To 176°F) |
| Communication Protocol | HART 6/7 |
| Diagnostics | Travel, Pressure, Supply Monitoring |
|---|---|
| Hazardous Area Certification | ATEX, IECEx, FM |
| Output Pressure | 0 - 100% Of Supply Pressure |
| Enclosure Rating | IP66/67, NEMA 4X |
| Rotation Angle | 0-90° Or 0-120° (for Rotary Valves) |
| Output Pressure | 0.1-10 Bar |
|---|---|
| Protection Class | IP66 |
| Communication | HART 7/Foundation Fieldbus |
| Operating Temp | -52°C–185°F (-62°C–85°C) |
| Input Signal | 4-20mA + HART/Foundation Fieldbus |
| Warranty | 1 YEAR |
|---|---|
| Customized Support | OEM |
| Model Number | 3200MD |
| Temperature Of Media | Low Temperature |
| Application | General |
| Output Modules | P/P (3-15 Psi) Or I/P (4-20 MA; Optional 10-50 MA) |
|---|---|
| Supply Pressure Tolerance | Up To 150 Psi Without External Regulator |
| Shock & Vibration Handling | Up To 2 G And 500 Hz Vibration Frequency Support |
| Signal Split Range | 2-, 3-, Or 4-way Split Range |
| Air Consumption | ~0.25 SCFM (steady State) / Up To 0.31 SCFM (I/P Module) |
| Integrated Booster | Optional (for High-speed Applications) |
|---|---|
| Communication Protocol | HART, Foundation Fieldbus, Profibus-PA |
| Enclosure Rating | IP66/67, NEMA 4X |
| Software Configuration | Flowserve Logix Software |
| Valve Characterization | Linear, Equal %, Quick Open (selectable) |
| Supply Pressure | Beta 5: 1.4-7 Bar (20-100 Psi) /Beta 7: 1.4-10 Bar (20-150 Psi) |
|---|---|
| Ambient Temperature | Standard: -40°C To +85°C (-40°F To +185°F) |
| Communication | HART 5/7, FF Foundation Fieldbus (Optional) |
| Application Industry | Oil & Gas, Chemical, Power Industry Valve Control |
| Ingress Protection (IP) | IP66/67 (Dust/Waterproof) |
| Accuracy | ±1%,±1.6% |
|---|---|
| Ambient Temperature | -20°C To +60°C |
| Diameter Nominal | 2.5"(63mm), 4"(100mm),6"(150mm) |
| Input Signal | 4-20 MA HART |
| Material | Aluminum |