| Media | Gas/Steam |
|---|---|
| Temperature Of Media | High Temperature, Low Temperature, Medium Temperature |
| Warranty | 1 Years |
| Connections | Flanged Inlet To ASME |
| Product Name | Direct Spring Pressure Relief Valves |
| Nominal Diameter At Inlet | DN 25 - DN 200 | 1" - 8" |
|---|---|
| Orifice | API Standard As Well As Extra Orifice: 1 D 2 - 8 T 10 / 1 G 2 - 8 T+ 10 |
| Actual Orifice Diameter D₀ | 11 - 180 Mm | 0.433 - 7.087 In |
| Actual Orifice Area A₀ | 95 - 25446.9 Mm² | 0.147 - 39.443 In² |
| Pressure | 2.5 - 426 Bar | 36 - 6170 Psig |
| Model | Spirax Sarco HV3 Bronze Bodied Globe Stop Valves For Steam Water Oil Air Applications With Handwheel |
|---|---|
| Connection Type | 2 Wire |
| Output Signal | 4 ~ 20 MA DC |
| Brand | Spirax Sarco |
| Bus/Sensor | 4-20 MA Transmitter |
| Nominal Diameter At Inlet | DN 25 - DN 100 | 1" - 4" |
|---|---|
| Orifice | G - P |
| Actual Orifice Diameter D₀ | 23 - 92 Mm | 0.906 - 3.622 In |
| Actual Orifice Area A₀ | 416 - 6648 Mm² | 0.644 - 10.304 In² |
| Pressure | 0.1 - 16 Bar | 1.5 - 232 Psig |
| Nominal Diameter At Inlet | DN 25 - DN 200 | 1" - 8" |
|---|---|
| Orifice | API Standard As Well As Extra Orifice: 1 D 2 - 8 T 10 / 1 G 2 - 8 T+ 10 |
| Actual Orifice Diameter D₀ | 11 - 190 Mm | 0.433 - 7.087 In |
| Actual Orifice Area A₀ | 95 - 25446.9 Mm² | 0.147 - 39.443 In² |
| Pressure | 2.5 - 256 Bar | 36 - 3705 Psig |
| Nominal Diameter At Inlet | DN 25 - DN 40 | 1" - 2" |
|---|---|
| Orifice | D - F |
| Actual Orifice Diameter D₀ | 13 - 25 Mm | 0.512 - 0.984 In |
| Actual Orifice Area A₀ | 133 - 491 Mm² | 0.206 - 0.761 In² |
| Pressure | 0.1 - 16 Bar | 1.5 - 232 Psig |
| Nominal Diameter At Inlet | DN15 - DN25 | 3/4" - 1" |
|---|---|
| Orifice | 0.5 X D |
| Actual Orifice Diameter D₀ | 10 Mm | 0.394 In |
| Actual Orifice Area A₀ | 78.5 Mm² | 0.122 In² |
| Pressure | 0.1 - 68 Bar | 1.5 - 986 Psig |
| Nominal Diameter At Inlet | DN 25 - DN 40 | 1'' - 2'' |
|---|---|
| Orifice | D - F |
| Actual Orifice Diameter D₀ | 13 - 25 Mm | 0.512 - 0.984 In |
| Actual Orifice Area A₀ | 133 - 491 Mm² | 0.206 - 0.761 In² |
| Pressure | 0.1 - 16 Bar | 1.5 - 232 Psig |
| Mounting Type | Direct Or Remote Mounting On Rotary Or Linear Control Valves |
|---|---|
| Communication Protocol | HART (Highway Addressable Remote Transducer) |
| Input Signal | 4-20 MA DC |
| Air Supply Pressure | 1.4 To 7 Bar (20 To 100 Psi) |
| Air Consumption | Approx. 0.4 Kg/h (at 1.4 Bar) |
| Valve Type | Floating Ball Valve, Ball Valve |
|---|---|
| Operating Temperature | Cryogenic, Low Temperature, Less Than 200 C |
| Material | 304 Stainless Steel, 316 Stainless Steel |
| Seat/Seal Type | Ball, Soft Seal |
| Media | Cryogenic, Liquid Propane, Liquid Propane Gas |